Section 4. Maintenance & Troubleshooting
SLCT-FAL5645 Sealing Machine
© Sealed Air Corporation (US)
MM-0110; Revision 1-A: 11/01/2013
4-3
4.1
MACHINE MAINTENANCE
Regular maintenance is the best way to ensure smooth operation and optimal machine life. The
following are the general machine maintenance guidelines. Only trained machine operators and
service technicians are authorized to perform maintenance on this machine.
IMPORTANT
Review and follow the Safety Guidelines in Chapter 1 of this Manual and site-specifi c
Lock Out/Tag Out Procedures when necessary.
• Maintenance of Pneumatic Regulator Unit:
When the water level reaches 2/3 of the height of the water fi lter tank, the tank water must be
drained out. To drain water, pull down the ring on the water drain plug.
Figure 4–1 Pneumatic Regulator Unit
• Clean the Workstation before the start operation each day.
a. Use only compressed air to clean the work area.
b. Only use soft wood to clear the fi lm reside on the sealing blade. Do not use metal or other
abrasive materials.
• Monthly Maintenance of the Selvage Receiving Wheel
a. Remove the locking nut, take out the spring and the receiving wheel.
b. Lubricate the contact surfaces of the receiving wheel and the center rod for smooth wheel
rotation
c. Replace the spring and receiving wheel and tighten the locking nut.
Water Drain