Revision 2.EL950 1.3.1074C 18.6
SET POINT
Displays the factory default Set Point temperature for each machine type. See Temp section for the specific
machine refrigeration modes. Ambient snack machines without a refrigeration system will display 36F.
These temperatures may be adjusted,
however it is not advised without direction by Seaga Customer
Care or an authorized technician.
The optimal temperatures have been set according to NAMA
specifications for optimal product safety. Before making any adjustment see Temp and Helath Safety
section.
DROP SENSOR
Allows you to adjust the Drop Sensor Sensitivity; 1 is most sensitive and 9 is least sensitive. The default
setting is 3 and should not need to be changed.
STEP
DISPLAY
1.
Press Service Mode Button
Motor Count or Error Code **
2.
Press 5 for Options Menu
Options
3.
Press 8 for Set Point
Setpoint (Current Setting)F *-Exit 8-Edit
4.
Press 8 to edit the temperature Set Point
Setpoint (Choice Flashing)F *-Exit #-Save
5.
Continue pressing 8 until the desired
temperature is shown on the display
Setpoint (New Temp)F *-Exit 8-Edit
6.
Press # to save the setting
Setpoint (New Setting)F *-Exit 8-Edit
6.
Press * three times to exit
0.00
STEP
DISPLAY
1.
Press Service Mode Button
Motor Count or Error Code **
2.
Press 5 for Options Menu
Options
3.
Press 9 for Drop Sensor
Drop Sensor (Current Setting) *-Exit 9-Edit
4.
Press 9 to edit the Drop Sensor sensitivity level
Drop Sensor (Choice Flashing) *-Exit #-Save
5.
Continue pressing 9 until the desired setting is
shown on the display
Drop Sensor (New Temp) *-Exit 9-Edit
6.
Press # to save the setting
Drop Sensor (New Setting) *-Exit 9-Edit
6.
Press * three times to exit
0.00