FEATURES AND SPECIFICATIONS
AC
(with lock in opening and closing position)
SC
(with lock only in closing position)
SA
(with lock only in opening position)
The
FULL TANK
is a high quality hydraulic operator for condominium use for gates with leaf lengths up to max. 7 m.
The lock is guaranteed for leaf lengths up to 180 m with the 270 version and up to 2,20 m with the 390 version. For leaf lengths
exceeding 2,20 m it is necessery, in all versions, to install an electric lock.
Available in the following versions:
SB
(without lock)
The Full Tank is supplied with by-pass valves for the power regulation in both opening and closing. Electronic adjustable slow
down in opening and closing with electronic control board. For the European laws and directives actually in force it is strongly
recommended to use the Safety Gate (device for the reading of the gate position), for reverse in case of obstacle.
Dimensions (
mm
)
FULL TANK
English
English
* Version with brake in c 25 mm
Version with brake in opening and
c 50 mm
Note
: The frequency of use is valid only for the first hour at 20°C room temperature.
Note
: in non-automatic logic, use operators without lock.
U
S
IN
G
G
R
A
P
H
IC
F
U
L
L
T
A
N
K
O
P
E
R
A
T
O
R
Sistemi Elettronici
di Apertura Porte e Cancelli
®
7 m
70
F
U
L
L
T
A
N
K
2
7
0
(2
3
0
V
-1
2
0
V
)
F
T
2
7
0
(2
3
0
V
-1
2
0
V
)
6 m
Fig. 1
0
7
1
5 *
FT
2
0
2
0 *
T
0
98
7
F
2
0
3
2
-
0
7
9
90
5
6
* F
12
70
T
39
0
21
T 3
1
9
5*
F
0
FULL TANK 270
FULL TANK 390
F
U
L
L
T
A
N
K
3
9
0
(2
3
0
V
-1
2
0
V
)
F
T
3
9
0
(2
3
0
V
-1
2
0
V
)
4 m
3 m
FU
LL
T
A
N
K
2
70
FA
ST
F
T
2
7
0
F
A
S
T
F
U
L
L
T
A
N
K
3
9
0
F
A
S
T
F
T
3
9
0
F
A
S
T
C
ic
le
s
/h
o
u
r
OPERATORS
M
a
x
.
le
a
f
le
n
g
th
Fig. 2
FT 270 (230V) FT 390 (230V) FT 270 (120V) FT 390 (120V)
FT 270 FAST FT 390 FAST
230V (±5%) 50/60 Hz 120V 60 Hz 230V (±5%) 50/60 Hz
220 W 300 W 310 W
1 A 2,45 A 1,5 A
270 mm 390 mm 270 mm 390 mm 270 mm 390 mm
1 cm/s 1,5 cm/s 1,2 cm/s 1,7 cm/s 3,35 cm/s
70
40 bar 30 bar 40 bar 35 bar
-20°C +55°C
130°C
640da N 480 daN 500 daN
12,5µF 60µF 12,5µF
12,8 kg 15,2 kg 12,8 kg 15,2 kg 13 kg 15,4 kg
IP55
6 m 7 m 6 m 7 m 3 m 4 m
90° / 125°
Fig. 3
TECHNICAL FEATURES
Operating temperatures
Thermal protection
M
P
Power supply
Power
Absorbed current
Stroke
Shaft speed
Cycles hour (at a temp. of 20°C)
Max working pressure
ax Thrust
Capacitor
Weight
rotection class
Max leaf lenght
Opening degree of the leaf
1
1
3
3
4
4
2
2
5
6
7
8
1
. Shaft cover
2
. Release
3
. Front bracket
4
. Rear bracket
5
. Cylinder
6
. Electric motor
7
. Hydraulic pump
8
. Exit electric cables
15