IQ Gate Systems 

 
 
 

 
 

IQ-500 Installation And 

Instruction Manual 

 
 
 
 
 
 

www.iqgatesystems.com

 

1-801-455-7961 

 
 
 
 
 
 
 
 
 
 
 
 
UL 325 and UL 991 Compliant  

 

 

 

Revision B 

Summary of Contents for IQ-500

Page 1: ...IQ Gate Systems IQ 500 Installation And Instruction Manual www iqgatesystems com 1 801 455 7961 UL 325 and UL 991 Compliant Revision B ...

Page 2: ...NE SHOULD CROSS THE PATH OF THE MOVING GATE Test the gate operator monthly The gate MUST reverse on contact with a rigid object or stop when an object activates the non contact sensors After adjusting the force or the limit of travel retest the gate operator Failure to adjust and retest the gate operator properly can increase the risk of injury or death Use the emergency release only when the gate...

Page 3: ...10 feet 5 Make sure that all warning signs have been attached and that the operator has been installed correctly 6 If edges and photoelectric sensors have been installed they should be tested for proper operation 7 Keep gates properly maintained Grease and lubricate all hinges and brackets to prevent binding and unnecessary friction 8 Have the operator tested and serviced by a qualified and experi...

Page 4: ... in which unauthorized access is prevented via supervision by security personnel The IQ 500 is a residential commercial swing gate operator 1 Install the gate operator only when The operator is appropriate for the construction of the gate see the ASTM F2200 standard and the usage UL Class of the gate It is recommended that all openings of a swing gate are guarded or screened from the bottom of the...

Page 5: ...in the line of sight of the gate Outdoor or easily accessible controls shall have a security feature to prevent unauthorized use 7 All warning signs and placards must be installed where visible in the area of the gate A minimum of two placards shall be installed A placard is to be installed in the area of each side of the gate and be visible to persons located on the side of the gate on which the ...

Page 6: ...or impeded by building structures natural landscaping or similar obstruction A wireless contact sensor shall function under the intended end use conditions Before installation Read and follow all instructions Verify that the IQ Gate Systems operator that is being installed is the correct operator for the gate Make sure that the gate has been properly installed and swings freely and level throughou...

Page 7: ...open and close force settings Improper testing and setting of the force adjustment can increase the risk of serious injury or death Mount all access controls away from the gate a recommended minimum distance of 10 feet The gate must be in full view of controls but out of reach After Installation Review ALL safety instructions with the end user Explain the basic operation and features including saf...

Page 8: ...sists of at least 20 watts AC power is recommended to consist of 110 to 220 volts AC power is the preferred method of supply Depending on soil conditions set the concrete pad at least 2 feet in the ground with an abundance of concrete Check and conform to local codes Install the gate with the incline of the road in mind For proper operation the gate must swing back and forth at a level plane For M...

Page 9: ...lize the Cat5e cable to terminate the open and close limit switches and the Encoder wires from the slave connection terminal block Connect these wires in the Master operator on the M 2 motor board The Encoder and the limit switches all utilize a common ground When programming the IQ Control Board for a Master Slave application be sure to change the number of operators in the Motor Drive Menu to 2 ...

Page 10: ...re the gate and operator for motion Properly secure and attach the desired form of power in the control box where power termination is labeled Attach the battery wires to the batteries after the AC power has been terminated and energized 10 ...

Page 11: ...ries must be connected in series and then the positive power wire RED is to be connected to the positive battery terminal For Solar powered IQ 500 operators the AC power supply should be disconnected and removed The Solar panel should be wired into the power terminal block or solar regulator if provided Take note of the software version on the LCD display upon power up 11 ...

Page 12: ...nserted in the Motor B terminal If the gate opens to the Left the Red wire should be inserted into the Motor B terminal with the Black motor wire being inserted into the Motor A terminal The open and close limit switch wires will need to be switched accordingly Limit Switches IQ 500 Left Hand Bottom limit switch is the open limit IQ 500 Right Hand Top limit switch is the open limit 12 ...

Page 13: ...commodate your entire accessory wiring needs The IQ control board uses pull down contacts so that the ground or GND terminals should be used as the common contact to complete the circuit for your normally open contacts The IQ control board also consists of 2 separate power output supplying areas The Red terminals located at the far most bottom right corner of the Terminal board are labeled 12V The...

Page 14: ...ion The EXIT detector will provide an open contact to the controller and will display Exit Loop Term The SAFE detector will provide a safe or close reversing contact to the controller and will display Safe Loop Term The AUX detector will provide the output contacts from the detector to the terminals on the board labeled A AUX B When a AUX loop is utilized and detecting the output from the detector...

Page 15: ...140ma 12vdc Use 24 vdc power To 24 vdc power 15 ...

Page 16: ... The IQ Control Board is also supplied with a programmable input terminal A contact closure between the AUX IN terminal and the GND terminal will activate the function that the input terminal has been programmed to do The output relay functions and input terminal options can be programmed in the Auxiliary Settings Menu Receive Transmit LED s Close limit terminal Open Limit Terminal Common Motor Wi...

Page 17: ...t the Clock Adjust Time Settings Auxiliary Settings Maintenance Menu Motor Drive Menu IQ Gate Learning Error and Fault Log To enter any of the menus rotate the programming knob one click to the right or clockwise The first option that will appear is Enter Password None This is indicating that the menu is not being password protected If the password feature was is being utilized then the appropriat...

Page 18: ...ammable 7 day auto open timers You can choose the time and days that the gates automatically open and then close There are 4 available auto open time slots To program adjust the desired time and then display what days you would like the timer to function If a day is undesired move the cursor under that day and press the programming knob to erase that day from the program Then scroll clockwise and ...

Page 19: ...pen limit o Pulse on Close Limit a 2 second relay activation on the close limit o Hold on Open Limit latches the relay on the open limit o Hold on Close Limit latches the relay on the close limit o Pulse on Motor Open a 2 second relay activation when gate is opening o Pulse on Motor Close a 2 second relay activation when gate is closing o Hold on Motor Open latches the relay when gate is opening o...

Page 20: ... relay for 3 seconds before motion Motion Warning Activates the alarm relay 3 seconds before motion as well as during gate motion Off no audible notification of gate motion Reset Password None or New press enter to setup a new password Limit Secure Off or On this is fail secure option recommended for use in the IQ 5000 only Input Contacts Momentary or Constant affects the OPEN and CLOSE inputs sho...

Page 21: ...ndard option does not require the feedback from an encoder from the motor M 1 Open Force user selectable amperage level from 00 1 to 16 0 Default 10 0 amps M 1 Close Force user selectable amperage level from 00 1 to 16 0 Default 10 0 amps Force Delay 0 5 recommended this is the selectable time from 5 seconds up to 2 seconds in which the amperage may be reached or exceeded before the gate reverses ...

Page 22: ...o to learn Close Count o I M 2 Close limit is _ _ _ _ counts o I M 2 Slow Down at _ _ this is the percent of gate travel that the soft stop would begin Encoding Failure Alarm and Stop or Alarm and Reverse Upon encountering an Encoder err the gate can be programmed to Stop and activate the Alarm relay or Reverse to an open or shut down position and activate the Alarm relay Exit the sub menu Error a...

Page 23: ...pen 5 When the gate reaches a desired open position immediately turn off the power switch on the side of the control box 6 Adjust the cam to activate the open limit at that point 7 Turn the On Off switch back on 8 Scroll to the Motor Drive Menu and select Number of Operators 1 and then select IQ Gate as the Operator IQ Scroll all the way clockwise and Exit the sub menu 9 Scroll to IQ Gate Learning...

Page 24: ...ckwise until the display reads Maintenance Menu and push enter to adjust Scroll clockwise until the display reads Motor Diagnostics View for M1 Off Press the programming knob to enter and the programming will be displayed Rotate the knob until ON is displayed press the programming knob again so that the disappears and then rotate the programming knob clockwise until Exit the sub menu and push the ...

Page 25: ...ers and the on screen messages troubleshooting the IQ Control Board is very easy if there is ever a problem that is encountered With the use of the on board RCV and XMIT green and orange blinking LED lights problems can easily be identified Some of the on screen messages that might be displayed are as followed M 1 Comm Lost M 2 Comm Lost Check the RCV and XMIT lights as well as the M1 M2 Motor sel...

Page 26: ...en Limit Close Limit M1C Lim Secure Close Limit Secured Safe L T 3min Active more then 3 Shadow 3min Active more then 3 M1O Lim Secure Open Limit Secured Close Detected Secured Input Secured Timer input Aux Term 3min Active more then 3 M1 Stuck Relay M2 Stuck Relay M 1 C L DIR ERR Wrong direction limit M 2 O L DIR ERR Wrong direction limit M 1 O L DIR ERR Wrong direction limit M 2 C L DIR ERR Wron...

Page 27: ... Check and remove shorts or over voltages Survey the area surrounding the gate when clear activate the UL Reset button terminal Check for any indication of power supplied Operate gate and view the blinking output from the Motor board terminal DS 10 Verify AUX IN setting and remove contact Increase force delay time to at least 0 5 seconds Gate Won t Close Low Power 7 day timer hold open Close timer...

Page 28: ...mmunication via the REC XMIT LED s Check and remove shorts or over voltages Check edge for activation failure Verify AUX IN setting and remove contact Increase force delay time to at least 0 5 seconds Gate reverses when closing Check all of the above causes Check the display for a M 1 or M 2 Close Force alert Check the Display and all LED s Check all of the above solutions Verify close force setti...