trailing edge, and post mounted both inside and outside of a
vehicular horizontal Swing gate.
•
One or more contact sensors shall be located at the bottom edge of
a vehicular vertical lift gate.
•
One or more contact sensors shall be located at the pinch point of a
vehicular vertical pivot gate.
•
A hardwired contact sensor shall be located and its wiring arranged
so that the communication between the sensor and the gate
operator is not subjected to mechanical damage.
•
A wireless contact sensor such as one that transmits radio
frequency (RF) signals to the gate operator for entrapment
protection functions shall be located where the transmission of the
signals are not obstructed or impeded by building structures,
natural landscaping or similar obstruction. A wireless contact
sensor shall function under the intended end-use conditions.
Before installation:
•
Read and follow all instructions
•
Verify that the IQ Gate Systems operator that is being installed is the
correct operator for the gate.
•
Make sure that the gate has been properly installed and swings freely and
level throughout its travel. Repair or replace any damaged or unsafe
hardware. A gate that swings free of friction and binding will greatly
increase the life of the gate operator.
•
Review the operation of the system and the customers needs to make the
installation as easy and efficient as possible.
•
This gate operator is intended for vehicular gates only. A separate
entrance must be provided for pedestrian use.
•
Please conform with the UL and ASTM standards on building safe and
approved gates
6