IQ Gate Learning – Enter if Applicable
(This menu is only used if “learning” IQ Gate Operators. This is the menu
that will allow you to set the desired closed limit as well as the location of the soft
stop in a percentage value. To LEARN an IQ Gate style gate operator, please
refer to the “Quick Start Guide” section of this manual.)
•
Enter for Motor 1 Learning Mode
o
Use ‘Radio’ to learn Close Count
o
I-M-1 Close limit is _ _ _ _ counts
o
I-M-1 Slow Down at _ _% (this is the percent of gate travel that the
soft stop would begin)
•
Enter for Motor 2 Learning Mode
o
Use ‘Radio’ to learn Close Count
o
I-M-2 Close limit is _ _ _ _ counts
o
I-M-2 Slow Down at _ _% (this is the percent of gate travel that the
soft stop would begin)
•
Encoding Failure = Alarm and Stop or Alarm and Reverse
Upon encountering an Encoder err, the gate can be programmed to Stop
and activate the Alarm relay, or Reverse to an open or shut-down position
and activate the Alarm relay.
Exit the sub-menu
Error and Fault Log – Press Enter to View
This menu will display the recent faults, errors, or important notifications
as well as the time and date that they occurred and what the recorded
temperature was at that time. You may scroll left or right and view the events as
they occurred with the date and time displayed. To
exit the sub-menu
, just press
the programming knob.
22