RISK EXAMINATION

The points pointed by arrows 

are potentially dangerous. The installer must take a thorough risk examination to prevent 

crushing, conveying, cutting, grappling, trapping so as to guarantee a safe installation for people, things and animals.
(

)

As for misunderstandings that may arise refer to your area distributor or call our help desk.   These instructions are part of the 

device and must be kept in a   well known place.The installer shall follow the 
provided intructions thoroughly. 

 products must only be used to automise 

doors, gates and lwings. Any initiative taken without 

 explicit authorization   

will preserve the manufacturer from whatsoever responsibility. The installer 
shall provide warning notices on not assessable further risks. 

 in its 

relentless aim to improve the products, is allowed to make whatsoever 
adjustment without giving notice. This   doesn’t oblige 

to up-grade the past 

production. 

 can not be deemed responsible for any damage or accident 

caused by product breaking, being damages or accidents due to a failure to 
comply with the instructions herein. The guarantee will be void and the 
manufacturer responsibility will be nullified if   

original spare parts are not 

being used. 

 Packaging materials such as plastic bags, foam 

polystyrene, nails etc must be kept out of children’s reach as dangers may arise. 

in fig. 27 

Re. Laws in force in the country where installation has been made.

SEA

SEA

SEA 

SEA 

SEA 

SEA 

The electrical installation shall be carried out by a professional 

technician who will release documentation as requested by the laws in force.

INITIAL TEST AND STARTING OF THE AUTOMATION 

After having completed the necessary operations for a correct installation of the Full Tank product, as described in this manual, 
and after having valuated all resting risks which could arise in any installation, 

it is necessary to test the automation to guaranty 

the maximum security and, in particular way, to 
guaranty that the laws and norms of this sector are 
fully respected

. Especially the test must be executed 

following the norm 

EN 12445

 which establishes the 

methods of tests for checking the gate automations 
respecting the limits established by the rule 

EN 12453.

 

SAFETY GATE

For a correct and safe installation it is strongly 
recommended to install a Safety Gate, 

which allows 

the fulfilment of the force diagram included in the 
norm EN 12453

 and consequently the test and start of 

the whole installation. 

SAFETY PRECAUTIONS:

All electrical work should conform to current regulations. A 16 A   0,030 A differential switch must be incorporated into the source of 
the operators main electrical supply and the entire system properly earth bonded. Always run mains carrying cables in separate 
ducts to low voltage control cables to prevent mains interference.

INTENDED USE:

The operator Full Tank has been planed to be used for the automation of swing gate operator only.

SPARE PARTS:

To obtain spare parts contact: 

SEA S.p.A. -Zona Ind.le, 64020 S. ATTO   Teramo   Italia

SAFETY AND ENVIRONMENTAL COMPATIBILITY:

Don’t waste product packing materials and/or circuits.
When being transported this product must be properly packaged and handled with care.

LIMIT OF GUARANTEE

For the guarantee see the sales conditions on the official SEA price list.

MAINTENANCE AND OUT OF SERVICE:

The decommission and maintenance of this unit must only be carried out by specialised and authorised personnel.

NOTE: THE MANUFACTURER CAN NOT BE DEEMED RESPONSIBLE FOR ANY DAMAGE OR INJURY CAUSED BY 
IMPROPER USE OF THIS PRODUCT.

   

SEA

 

reserves the right to do changes or variations that may be necessary to its products with no obligation to notice.

FULL TANK

English

English

Fig.28

Sistemi Elettronici

di Apertura Porte e Cancelli

®

26

Summary of Contents for full tank

Page 1: ...RTAIL BATTANTS ACTUADOR OLEODINAMICO PARA CANCELAS ABATIBLES Sistemi Elettronici di Apertura Porte e Cancelli International registered trademark n 804888 MANUALE D INSTALLAZIONE ed informazioni sulla...

Page 2: ...ture Note in non automatic logic use operators without lock USING GRAPHIC FULL TANK OPERATOR Sistemi Elettronici di Apertura Porte e Cancelli 7 m 70 FULL TANK 270 230V 120V FT 270 230V 120V 6 m Fig 1...

Page 3: ...s Attachment Rear attachment Breather screw Pin rear attachment short Brass Pin long Front bracket Shaft Cover End cover Fig 4 Shaft FULL TANK English English Oil fill in cover Sistemi Elettronici di...

Page 4: ...TYPE OF INSTALLATION It is possible to install the FullTank with opening inside Fig 5 or opening outside Fig 6 Install the operator always inside the property inside inside Outside Outside Inward inst...

Page 5: ...5 90 90 95 95 100 105 110 120 130 110 90 110 90 106 90 90 100 90 100 90 90 96 90 92 92 250 250 250 250 250 253 245 Max Stroke mm Stroke for 90 mm Total stroke 390 mm max recommended stroke 370 mm a b...

Page 6: ...90 80 80 70 65 95 90 95 90 90 90 250 249 Stroke max mm Stroke for 90 mm Total stroke 270 mm max recommended stroke 250 mm a b Max Opening angle mm mm 356 342 345 336 330 335 319 250 255 265 270 275 2...

Page 7: ...L TANK English English INSTALLATION ON MASONRY PILLARS MAKING A NICHE Version 270 mm Version 390 mm Fig 9 If you have to make a niche observe the dimensions shown in fig 9 DIMENSIONS EN mm a d b 55 15...

Page 8: ...er than the allowed angle of the oscillating bracket 1 risks the possible braking of it INSTALLATION OF THE OSCILLATING REAR BRACKET Adjustable rear bracket with screws Accessory on demand INSTALLATIO...

Page 9: ...and mark the position of the front bracket Fig 16 Attention avoid the welding of the front bracket to the shaft of the hydraulic operator already attached the welding scraps daps could ruin the chromi...

Page 10: ...st Release the unit Make the shaft come out for of its stroke Put the positive stops into the front flange of the unit with the two tie rods of the three present on the stops which are parallel to the...

Page 11: ...operator at the end of installation TORQUE ADJUSTMENT by pass valves By Pass Valves s u s e r r e p in g n o i t p a e r n e i n p g O u ss e r re p i g n n i c t lo a r s e i n p g O Grey Yellow Grey...

Page 12: ...SWITCH POSITIVE STOPS FLASHING LAMP CONTROL UNIT SUPPORTS FOR PHOTOCELLS FULL TANK ACCESSORIES FULL TANK English English The oil level should be measured with the rod inserted into the actuator and mu...

Page 13: ...fter having valuated all resting risks which could arise in any installation it is necessary to test the automation to guaranty the maximum security and in particular way to guaranty that the laws and...

Page 14: ...is necessary to repeat the test and the putting in service of the automation Lubricate the shaft see Fig 4 with SEAgrease GREASE GL00 Cod 65000009 PERIODICAL MAINTENANCE Annual Annual 4 years Annual A...

Page 15: ...il medesimo nella propria attivit di rivendita e o installazione secondo modalit che non ne riducano in alcun modo i diritti a non rimuovere sostituire o alterare marchi o altri segni distintivi di qu...

Page 16: ...nd or be a source of danger SEA S p A declines all liability caused by improper use or different use in respect to the intended one 4 The mechanical parts must be comply with Directives Machine Regula...

Page 17: ...e el sistema automatizado fue producido 4 Los productos cumplen con la Directiva Maquinas 2006 42 CE y siguientes modificaciones Baja Tension 2006 95 CE y siguientes modificaciones Compatibilidad Elec...

Page 18: ...tarie 2006 95 CE e 2004 108 CE it is conforming to the essential safety requirements related to the product within the field of applicability of the Community Directives 2006 95 CE and 2004 108 CE COS...

Page 19: ..._________________________________ Nome e Cognome First and Family Name_________________________________ Indirizzo Address ____________________________________________________ INSTALLATORE INSTALLER Fi...

Page 20: ...ttronici di Apertura Porte e Cancelli International registered trademark n 804888 SEA S p A Zona industriale 64020 S ATTO Teramo ITALY Tel 39 0861 588341 r a Fax 39 0861 588344 www seateam com seacom...

Reviews: