background image

CERTIFICATO DI ESTENSIONE GARANZIA

CERTIFICATE OF WARRANTY EXTENTION

PRODOTTO/ PRODUCT

- Modello/

Model____________________________________________________

- Matricola n. /

Serial Number_________________________________________

- Data di acquisto/

Date of order________________________________________

- Data di installazione/

Date of installation_______________________________

Centrale/Control unit                            
Fotocellule/Photocells                            
RX - TX                                                   
Altri accessori /Other accessories        

SEA
SEA
SEA
SEA

Altri/

Others

Altri/

Others

Altri/

Others

Altri/

Others

UTENTE/Customer

Nome e Cognome_____________________________________________________

First Name and Family Name 

_________________________________________

Indirizzo/Address_____________________________________________________
___________________________________________________________________

  

INSTALLATORE/Installer

Ragione sociale/

Company Name 

________________________________________

Nome e Cognome/

First and Family Name

_________________________________

Indirizzo/

Address 

____________________________________________________

INSTALLATORE

/

INSTALLER

Firma per il trattamento dei dati personali 196/2003
Agreement of law No. 196/2003 (Privacy Code)

Firma e Timbro

Sign and Stamp     

___________________________

Copia da restituire

Copy to be returned

N.B: L’estensione della garanzia legale di 12 mesi a 24 mesi e 36 mesi è va-
lida solo se il presente modulo viene rispedito per posta o fax a SEA
S.p.A. entro 15gg dalla data di acquisto. Allegare relativa fattura d’acquisto.
-   -   -   -   -   -   -   -   -   -   -

S.p.A

Note: The extension of the legal standard warranty of 12 months to 24 months
and to 36 months, is valid only if the present form is returned by mail or fax to
SEA 

 within 15days from the date of purchase. Attach customer invoice.

Sistemi Elettronici

di Apertura Porte e Cancelli

International registered trademark n. 804888

®

SEA S.p.A. - Zona Industriale San Atto- 64020 Teramo (Italy)

Phone +39 0861 588341- Fax +39 0861588344

www.seateam.com - [email protected]

n

.

C

C

Summary of Contents for full tank

Page 1: ...RTAIL BATTANTS ACTUADOR OLEODINAMICO PARA CANCELAS ABATIBLES Sistemi Elettronici di Apertura Porte e Cancelli International registered trademark n 804888 MANUALE D INSTALLAZIONE ed informazioni sulla...

Page 2: ...ture Note in non automatic logic use operators without lock USING GRAPHIC FULL TANK OPERATOR Sistemi Elettronici di Apertura Porte e Cancelli 7 m 70 FULL TANK 270 230V 120V FT 270 230V 120V 6 m Fig 1...

Page 3: ...s Attachment Rear attachment Breather screw Pin rear attachment short Brass Pin long Front bracket Shaft Cover End cover Fig 4 Shaft FULL TANK English English Oil fill in cover Sistemi Elettronici di...

Page 4: ...TYPE OF INSTALLATION It is possible to install the FullTank with opening inside Fig 5 or opening outside Fig 6 Install the operator always inside the property inside inside Outside Outside Inward inst...

Page 5: ...5 90 90 95 95 100 105 110 120 130 110 90 110 90 106 90 90 100 90 100 90 90 96 90 92 92 250 250 250 250 250 253 245 Max Stroke mm Stroke for 90 mm Total stroke 390 mm max recommended stroke 370 mm a b...

Page 6: ...90 80 80 70 65 95 90 95 90 90 90 250 249 Stroke max mm Stroke for 90 mm Total stroke 270 mm max recommended stroke 250 mm a b Max Opening angle mm mm 356 342 345 336 330 335 319 250 255 265 270 275 2...

Page 7: ...L TANK English English INSTALLATION ON MASONRY PILLARS MAKING A NICHE Version 270 mm Version 390 mm Fig 9 If you have to make a niche observe the dimensions shown in fig 9 DIMENSIONS EN mm a d b 55 15...

Page 8: ...er than the allowed angle of the oscillating bracket 1 risks the possible braking of it INSTALLATION OF THE OSCILLATING REAR BRACKET Adjustable rear bracket with screws Accessory on demand INSTALLATIO...

Page 9: ...and mark the position of the front bracket Fig 16 Attention avoid the welding of the front bracket to the shaft of the hydraulic operator already attached the welding scraps daps could ruin the chromi...

Page 10: ...st Release the unit Make the shaft come out for of its stroke Put the positive stops into the front flange of the unit with the two tie rods of the three present on the stops which are parallel to the...

Page 11: ...operator at the end of installation TORQUE ADJUSTMENT by pass valves By Pass Valves s u s e r r e p in g n o i t p a e r n e i n p g O u ss e r re p i g n n i c t lo a r s e i n p g O Grey Yellow Grey...

Page 12: ...SWITCH POSITIVE STOPS FLASHING LAMP CONTROL UNIT SUPPORTS FOR PHOTOCELLS FULL TANK ACCESSORIES FULL TANK English English The oil level should be measured with the rod inserted into the actuator and mu...

Page 13: ...fter having valuated all resting risks which could arise in any installation it is necessary to test the automation to guaranty the maximum security and in particular way to guaranty that the laws and...

Page 14: ...is necessary to repeat the test and the putting in service of the automation Lubricate the shaft see Fig 4 with SEAgrease GREASE GL00 Cod 65000009 PERIODICAL MAINTENANCE Annual Annual 4 years Annual A...

Page 15: ...il medesimo nella propria attivit di rivendita e o installazione secondo modalit che non ne riducano in alcun modo i diritti a non rimuovere sostituire o alterare marchi o altri segni distintivi di qu...

Page 16: ...nd or be a source of danger SEA S p A declines all liability caused by improper use or different use in respect to the intended one 4 The mechanical parts must be comply with Directives Machine Regula...

Page 17: ...e el sistema automatizado fue producido 4 Los productos cumplen con la Directiva Maquinas 2006 42 CE y siguientes modificaciones Baja Tension 2006 95 CE y siguientes modificaciones Compatibilidad Elec...

Page 18: ...tarie 2006 95 CE e 2004 108 CE it is conforming to the essential safety requirements related to the product within the field of applicability of the Community Directives 2006 95 CE and 2004 108 CE COS...

Page 19: ..._________________________________ Nome e Cognome First and Family Name_________________________________ Indirizzo Address ____________________________________________________ INSTALLATORE INSTALLER Fi...

Page 20: ...ttronici di Apertura Porte e Cancelli International registered trademark n 804888 SEA S p A Zona industriale 64020 S ATTO Teramo ITALY Tel 39 0861 588341 r a Fax 39 0861 588344 www seateam com seacom...

Reviews: