All the above described operations MUST be made exclusively by an authorized installer.
1) Check the solidity and the stability of the gate, especially the points of support and/or rotation of
the gate (pivots).
2)
Check the oil level of the hydraulic/in oil bath operators (cap on rear cover of the Full Tank)
3)
Change the hydraulic oil with the one recommended from the head company
4)
Check the release function
5)
Check the by-pass valves function
6)
Check and lubricate the fixing pins
7)
Check the integrity of the connection cables
8)
Check the function and the positive stops condition in opening and closing (where there is
present a mechanical positive stop accessory)
9)
Check the good status of all parts which are forced (rear bracket, oscillating bracket and front
bracket).
10) Check the operating of all accessories, especially the function of all safety devices and of the
Safety Gate.
11)
12)
After having executed the periodical maintenance operations it is necessary to repeat the
test and the putting in service of the automation
Lubricate the shaft (see Fig.4) with SEA grease (GREASE GL 00 Cod.65000009)
PERIODICAL MAINTENANCE
Annual
Annual
4 years
Annual
Annual
Annual
Annual
Annual
Annual
Annual
Annual
Annual
WARNING:
SEA recommends to the end user to release the operator only after having switched off the electric power.
Always contact a professional installer in case of not correct working of the operator.
To the attention of users and technicians
FULL TANK
English
English
RELEASE SYSTEM
To release operate as follows:
open the lock cover, insert the key, turn it about 90° clockwise (see fig.29) and open the lid.
Take the red key located under the lid, insert it and turn it about 90° anti-clockwise (see fig.30).
To relock the operator do as follows:
turn the red key clockwise until it stops (see fig.30), remove it, put it under the lid
and close the lid again.
Attention: Turning the key over 1 turn (360°) could damage the release.
Turn the key anti-clockwise to tighten the lid, remove the key and close the lock cover.
Fig. 29
Fig. 30
Op
n
e
Clo
e
s
e
Rel
ase
ock
L
27
Sistemi Elettronici
di Apertura Porte e Cancelli
®