3. Ensure that the pump oil level is even with or higher than the center of the pump sight glass. Damage to the
High Pressure Pump will occur if the wrong oil is used in its crankcase or if the oil level is not at minimum
required level. Use only Sea Recovery supplied pump oil. The supplied Pump Oil is special hydraulic oil, which
contains anti rust and wear inhibitors essential to the high-pressure pump crankcase section.
4. Ensure that the tube shipping plug has been removed from the Potable Water outlet port of the Water Control
Manifold and that 1/4” product water tube is connected.
5. Reverse Osmosis Element:
Caution:
Some systems are shipped WITHOUT the Reverse Osmosis Membrane Element. This is to
accommodate, for example, Boat Builders that install the system well in advance of commissioning the
boat and the Aqua Mini 170 - 750.
If the Reverse Osmosis Membrane Element has been installed, there will be a Reverse Osmosis Membrane
Element Serial Number tag, illustrated below, attached to the High Pressure Vessel. Find this Serial Number
tag to ensure that the R.O. Membrane Element has been installed.
If the R.O. Membrane Element Serial Number tag is missing or does not contain a serial number and date, then
immediately contact the company that sold the system to you, the installer, or Sea Recovery.
DO NOT attempt to operate the system without a Reverse Osmosis Membrane Element installed in the
system otherwise extensive damage will result.
Sea Recovery
Rancho Dominguez, California 90220 U.S.A.
Tel: 1-310-637-3400 ¦ Fax: 1-310-637-3430
Email: [email protected]
087945021505
BRINE INLET END
SERIAL NO:
FLOW:
--›
DATE:
6. Check each tube connection to the system to ensure that the installer has properly connected and properly
routed each tube. Improper routing and any blockage in any line causes damage to the system.
Do not rely
on the installer’s word; check it yourself.
7. Make sure that the Electrical Power Source, boat’s circuit breaker to the system, is switched "OFF".
8. Open the front panel of the Main Power Enclosure and check all electrical and electronic connections for proper
wiring and attachment. Refer to the wiring diagrams in this section.
9. Close the Main Power Enclosure front panel.
10. Ensure that the manual By-Pass lever on the Diversion Valve [21] is positioned outward (away from the coil
body).
11. Open any auxiliary valve within the incoming Feed Line, Outgoing Brine Discharge Line, and Outgoing Product
Water Line.
Caution:
If any auxiliary valve is installed in these lines, it will damage the Aqua Mini if left closed during
starting and/or operation of the system.
12. Open the Back Pressure Regulator Valve [17] FULLY OPEN by turning counter clockwise.
Caution:
The Back Pressure Regulator Valve [17] must be fully open when starting the Aqua Mini 170 -
750. If this valve is left closed, it will cause damage to the system.
13. Switch the Electrical Power Source, boat’s circuit breaker to the system "ON".
14. HIGH PRESSURE ELECTRIC MOTOR ROTATIONAL CHECK:
Ask an assistant to view the fan section of the Booster Pump Motor [4] and High Pressure Pump Motor.[10]
while you “Jog” the system.
39
System Installation Precautions and Information
Summary of Contents for Aqua Mini 170
Page 2: ......
Page 4: ......
Page 12: ......
Page 18: ......
Page 28: ......
Page 48: ......
Page 66: ......
Page 71: ...Wiring Diagram Aqua Mini 24vdc 69 Electrical...
Page 73: ...71 Electrical...
Page 74: ......
Page 90: ......
Page 97: ...Chapter 12 Exploded Parts View 95...
Page 146: ...1 1 15 11 5 13 6 14 11 5 16 3 8 7 9 4 12 10 2 Sea Recovery Aqua Mini 170 350 550 and 750 144...
Page 148: ...5 7 11 2 1 2 10 6 3 8 4 9 6 3 Sea Recovery Aqua Mini 170 350 550 and 750 146...
Page 153: ...12 8 9 2 10 13 1 3 5 4 14 11 6 15 7 151 Exploded Parts View...
Page 155: ...1 153 Exploded Parts View...
Page 162: ......
Page 163: ...Chapter 13 Appendix 161...
Page 164: ......
Page 165: ......
Page 166: ...FCC Compliance 163 Appendix...