6. If leaks are found on the compression nuts, depressurize the unit and slightly tighten the leaking compression
nut.
7. Retest until a leak-free installation is verified.
8. Once UV unit is leak-free, the quartz sleeve installation is complete and the UV lamp can be installed.
Note:
To remove tube from fitting, first remove the C-clamp then push fitting sleeve down. Once the fitting
sleeve is down, pull the tube out of the fitting.
Install Ultraviolet Lamp
Perform this procedure only after the quartz sleeve installation and leak-tests are completed successfully
1. Connect the UV lamp to the 4-point receptacle. If the lamp is not installed properly, lamp breakage will occur.
2. Insert lamp into quartz sleeve through compression nut pass-thru.
3. Install rubber boot over compression nut
4. Connect unit power cable to power source.
5. Tighten the 4 screws to secure ballast box cover.
6. Turn ON the power to the unit.
7. Verify UV lamp operation from the viewport.
8. Allow one minute for the UV lamp to warm up prior to flowing water through the UV unit.
Caution:
Use the viewport to verify the proper operation of the UV lamp.
Caution:
Rapid successive cycling of the power to the ballast can cause premature failure of the unit.
Caution:
Prior to energizing the lamp, make sure there is no water leaking from the quartz sleeve
compression nuts.
Mounting the Unit
Once the UV unit is assembled and tested successfully, it can be mounted onto its permanent operational location.
The unit must be mounted in a manner that will prevent excessive vibration and warping which will damage the
quartz sleeve.
Operational Guidelines
1. Release the pressure in the UV treatment chamber before breaking the compression nut seals.
2. Disconnect all power to the UV unit before servicing.
3. Do not allow the inlet water temperature to drop below 35ºF (2ºC).
4. Do not allow the flow rate to exceed 2 GPM.
5. Do not cycle the UV unit more than 3 “ON/OFF” cycles in a 24-hour period.
6. Ensure all plumbing connections are tightly sealed before applying pressure.
7. Before connecting the return tube, flush the unit to rinse out any debris left from the installation process.
Danger:
UV LIGHT EXPOSURE CAN SEVERELY BURN AND DAMAGE EYES AND SKIN.
Danger:
DO NOT look at the blue UV light. DO NOT operate the UV lamp outside of the UV treatment
chamber.
Caution:
The unit operates on high voltage and must be serviced by qualified personnel only.
Caution:
Standard flow rate are based on water temperature 35ºF to 100ºF. If the inlet water temperature
exceeds 100ºF (38ºC), please contact your local CSR.
35
System Installation Precautions and Information
Summary of Contents for Aqua Mini 170
Page 2: ......
Page 4: ......
Page 12: ......
Page 18: ......
Page 28: ......
Page 48: ......
Page 66: ......
Page 71: ...Wiring Diagram Aqua Mini 24vdc 69 Electrical...
Page 73: ...71 Electrical...
Page 74: ......
Page 90: ......
Page 97: ...Chapter 12 Exploded Parts View 95...
Page 146: ...1 1 15 11 5 13 6 14 11 5 16 3 8 7 9 4 12 10 2 Sea Recovery Aqua Mini 170 350 550 and 750 144...
Page 148: ...5 7 11 2 1 2 10 6 3 8 4 9 6 3 Sea Recovery Aqua Mini 170 350 550 and 750 146...
Page 153: ...12 8 9 2 10 13 1 3 5 4 14 11 6 15 7 151 Exploded Parts View...
Page 155: ...1 153 Exploded Parts View...
Page 162: ......
Page 163: ...Chapter 13 Appendix 161...
Page 164: ......
Page 165: ......
Page 166: ...FCC Compliance 163 Appendix...