9. Tank Empty – Yes or no
10. Booster Relay - Booster pump on or off
11. FWF Relay – Fresh Water Flush on or off
12. HP Relay – High pressure pump on or off
13. DV Relay – Diversion valve on or off
14. UV Relay – Ultraviolet on or off
15. Supply Voltage – volts (used only for diagnostics)
16. Version – software version
Configuration (Change) Menu
This menu shows a list of configuration parameters that can be changed by the operator. Press the CYCLE button
and hold for 5 seconds to view this menu and CYCLE again to scroll through the menu items. Every time CYCLE
is pressed, the next item is shown. Holding the CYCLE button for more than 5 seconds selects the displayed menu
item. Note that this menu does not allow the operator to monitor the state of these configuration parameters. Please
use the Configuration (Read) Menu to do so.
1. Unit – units (metric or US)
2. Low Pressure 1 Inst – S1 Lo pressure sensor installed (yes or no)
3. Low Press 2 Inst – S2 Lo pressure sensor installed (yes or no)
4. Prod Flow Inst – Product flow meter installed (yes or no)
5. Brine Flow Inst – Brine flow meter installed (yes or no)
6. Tank Full Inst – Tank level full sensor installed (yes or no)
7. Tank Empty Inst – Tank level empty sensor installed (yes or no)
8. FWF Delay – High pressure pump stop to FWF delay (HH:mm:ss)
9. Time to AutoShut – Auto shutdown after X hours in state FWP (HH:mm:ss)
10. AutoShut Time – Auto shutdown after time (yes or no)
11. AutoShut Tank – Auto shutdown on tank full (yes or no)
12. FWF Duration – FWF duration time (HH:mm:ss)
13. FWF Interval – FWF interval time (HH:mm:ss)
14. PassiveUVoff – Time from leaving fresh water production to turning UV off (HH:mm:ss)
15. UV off delay – Time from UV on to diversion valve to tank (HH:mm:ss)
16. AutoStart Tank – Autostart on tank empty (yes or no)
17. BP Delay – Time from feed pump to high pressure pump/ETD (HH:mm:ss)
18. Salinity Level – Salinity error level (ppm)
19. Min Pressure – minimum pressure (Bar or PSI)
20. Min Pressure Time – Min pressure measure time (HH:mm:ss)
21. Max Pressure – Maximum pressure (Bar or PSI)
22. Sol. Valve Time – Solenoid valve time (seconds)
Configuration (Read) Menu
This menu monitors a selected list of configuration parameters, which may be of interest to the operator (e.g. units
are metric or US, FWF time interval, etc.). This menu is appended to the Display Menu.
1. Unit – units (metric or US)
2. Low Pressure 1 Inst – S1 Lo pressure sensor installed (yes or no)
3. Low Press 2 Inst – S2 Lo pressure sensor installed (yes or no)
4. Prod Flow Inst – Product flow meter installed (yes or no)
5. Brine Flow Inst – Brine flow meter installed (yes or no)
6. Tank Full Inst – Tank level full sensor installed (yes or no)
7. Tank Empty Inst – Tank level empty sensor installed (yes or no)
8. Time to AutoShut – Auto shutdown after X hours in state FWP (HH:mm:ss)
9. AutoShut Time – Auto shutdown after time (yes or no)
10. AutoShut Tank – Auto shutdown on tank full (yes or no)
11. FWF Duration – FWF duration time (HH:mm:ss)
Sea Recovery Aqua Mini 170, 350, 550 and 750
44
Summary of Contents for Aqua Mini 170
Page 2: ......
Page 4: ......
Page 12: ......
Page 18: ......
Page 28: ......
Page 48: ......
Page 66: ......
Page 71: ...Wiring Diagram Aqua Mini 24vdc 69 Electrical...
Page 73: ...71 Electrical...
Page 74: ......
Page 90: ......
Page 97: ...Chapter 12 Exploded Parts View 95...
Page 146: ...1 1 15 11 5 13 6 14 11 5 16 3 8 7 9 4 12 10 2 Sea Recovery Aqua Mini 170 350 550 and 750 144...
Page 148: ...5 7 11 2 1 2 10 6 3 8 4 9 6 3 Sea Recovery Aqua Mini 170 350 550 and 750 146...
Page 153: ...12 8 9 2 10 13 1 3 5 4 14 11 6 15 7 151 Exploded Parts View...
Page 155: ...1 153 Exploded Parts View...
Page 162: ......
Page 163: ...Chapter 13 Appendix 161...
Page 164: ......
Page 165: ......
Page 166: ...FCC Compliance 163 Appendix...