3. 30 feet (9.14 meters) of 1/4” (6.35 mm) OD nylon tubing is supplied for connecting:
Inlet of
to
Outlet of
Charcoal Filter {22}
Potable Product Water from System
U.V. Sterilizer [23]
Charcoal Filter [22]
pH Neutralizing Filter
U.V. Sterilizer [23]
Boats Potable Water Storage Tank [24]
pH Neutralizing Filter
High Pressure Pump Preparation
1. Remove the shipping tape from the High Pressure Pump Oil Fill Cap to expose the Oil Fill Cap air breather
hole.
2. Ensure that the pump oil level is even with or higher than the center of the pump sight glass. Damage to the
High Pressure Pump will occur if the wrong oil is used in its crankcase. Use only Sea Recovery supplied pump
oil.
Tools Required for Installation
Not all installations are typical, therefore, it is recommended to have a full set of Mechanic’s and Electrician’s tools
available. No special system tools are required for installation. A separate TDS Meter, available from Sea Recovery
will assist in confirming system product water quality. A volt/ohm meter (VOM) is required for system installation
and commissioning to ensure proper electrical power and connection.
Components Supplied by Installer or Owner
Caution:
All fittings, valving, and piping installed prior to, within, and after the Sea Recovery system must
not contain iron. They must be non-ferrous material (not containing iron). Iron fittings or piping will cause rust
fouling and failure of the R.O. Membrane Element. The resulting failure of the R.O. Membrane Element is
attributed to improper installation, is the liability of the installer, and is not covered by the Sea Recovery
warranty.
1. Water Connections to be supplied by the installer
Table 9: Aqua Mini 170
5/8” MNPT Male National Pipe Thread Standard
Feed Inlet:
1/2” MNPT Male National Pipe Thread Standard
Brine Discharge
1/4” FNPT Female National Pipe Thread Standard
Product
Table 10: Aqua Mini 350, 550 & 750
5/8” MNPT Male National Pipe Thread Standard
Feed Inlet:
1/2” MNPT Male National Pipe Thread Standard
Brine Discharge
1/4” FNPT Female National Pipe Thread Standard
Product
2. Inlet Thru Fitting with Forward Facing Scoop [1].
The inlet Thru Hull Fitting must be dedicated to only the Sea Recovery system. It is important that the installer
utilizes a forward facing scoop so that the system receives a positive flow of water as the boat is under way. The
fitting must be installed on the boats hull in a position that provides continual feed water flow without air to the
system.
29
System Installation Precautions and Information
Summary of Contents for Aqua Mini 170
Page 2: ......
Page 4: ......
Page 12: ......
Page 18: ......
Page 28: ......
Page 48: ......
Page 66: ......
Page 71: ...Wiring Diagram Aqua Mini 24vdc 69 Electrical...
Page 73: ...71 Electrical...
Page 74: ......
Page 90: ......
Page 97: ...Chapter 12 Exploded Parts View 95...
Page 146: ...1 1 15 11 5 13 6 14 11 5 16 3 8 7 9 4 12 10 2 Sea Recovery Aqua Mini 170 350 550 and 750 144...
Page 148: ...5 7 11 2 1 2 10 6 3 8 4 9 6 3 Sea Recovery Aqua Mini 170 350 550 and 750 146...
Page 153: ...12 8 9 2 10 13 1 3 5 4 14 11 6 15 7 151 Exploded Parts View...
Page 155: ...1 153 Exploded Parts View...
Page 162: ......
Page 163: ...Chapter 13 Appendix 161...
Page 164: ......
Page 165: ......
Page 166: ...FCC Compliance 163 Appendix...