Fig. 3  Basic Door Installation  

Fig. 4  Basic Door Installation Wiring

C

NC

NO

C

NC

NO

NC DOOR 

POSITION SWITCH

NO REQUEST-TO-

EXIT SWITCH

SENSE

GROUND

REQUEST-TO-EXIT

GROUND

GROUND

GROUND

OUTPUT #3

OUTPUT #4

EARTH 

GROUND 

CONNECTION

A

c

c

e

s

s

o

ry

 T

e

rm

in

a

ls

8

7

6

5

4

3

2

1

TO POWER SUPPLY

KEY PAD POWER

12-24 VOLTS

AC OR DC

}

+

-

AUXILIARY RELAY

2 AMPS @ 28VDC 

MAX

}

NC

NO

COM

FAIL SECURE CONNECTION

FAIL SAFE CONNECTION

MAIN RELAY

5 AMPS @ 28VDC 

MAX

}

NC

COM

NO

M

a

in

 R

e

la

y

1

2

3

A

u

x

 R

e

la

y

1

2

3

K

P

 P

w

r

1

2

P:\INSTALLATION INST\Access Controls\INST-924\INST-924P.vsd     Rev C     10-14     Page 4

Fig. 5  Using Solid State Outputs

OUTPUT #3 LIGHTS AN LED
OUTPUT #4 LIGHTS AN LED AND SOUNDS A BEEPER

EXAMPLE #1:

POWER
SUPPLY

+

LED

LED

1KΩ

1KΩ

-

+

OUTPUT #3

OUTPUT #4

ELECTRONIC 

BEEPER

OUTPUT #3 LIGHTS A LAMP POWERED FROM AN EXTERNAL SOURCE
OUTPUT #4 TRIGGERS A NORMALLY OPEN ALARM PANEL ZONE

EXAMPLE #2:

OUTPUT #3 COM

OUTPUT #4 COM

POWER 

SOURCE

OUTPUT #3

END OF LINE 

RESISTOR

ALARM PANEL

NO ZONE

COMMON

LOW 

VOLTAGE 

LAMP

-

+

OUTPUT #4

EACH 

OUTPUT 

100 mA 

MAXIMUM

A

c

c

e

s

s

o

ry

 T

e

rm

in

a

ls

3

2

1

4

A

c

c

e

s

s

o

ry

 T

e

rm

in

a

ls

3

2

KEYPAD WIRING

See Fig. 3 for an example of a basic door installation.  The keypad is 
mounted adjacent to the door.  An electric door strike is mounted in the 
door jamb to release the door lock.  A magnetic switch is mounted on top 
of the door jamb for detecting when the door is open.

Use the following steps to wire the keypad.  Refer to the wiring diagram 
shown in Fig. 4 to assist in the wiring.

Note: Up to 500 feet of 18 AWG wire can be run for power, use larger wire 
for longer runs.  Use 22 AWG or larger (depending on load) for other 
connections.

Output

Install a low voltage fail-secure electric door strike for unlocking the 
door.
Route two wires between the door strike and the external controller. 
Connect a MOV or varistor across the coil wires of the strike. 
Connect the (+) door strike wire to the keypad’s MAIN RELAY N.O. 
terminal.  Connect the other door strike wire to the keypad’s PWR (-) 
terminal.  Connect a wire between the keypad’s PWR (+) terminal and 
the MAIN RELAY COM terminal.

Power

Choose a location for the DC power supply or AC transformer.
Connect the power supply’s output terminals to the keypad’s PWR  
(+) and (-) terminal. Observe wiring polarity if using DC.  If AC is 
being used, polarity does not mater.

Caution:  If the unit is AC powered, make sure the secondary of 
the system transformer is isolated from earth ground.

Earth Ground

To avoid damage to the unit from static discharges, connect the 
EARTH GROUND to E1, E4, E5 or E7 to a good earth grounding 
point.  Suggested wiring size is 18 AWG for earth ground.

Sense Input

RE 

Note:  The SENSE input (E8) can be programmed for either a door 

sense or inhibit input.  Both features cannot be used at the same time. If 
you are not using the sense input, program the input for inhibit.

To use the door sense feature to detect forced entry or door ajar 
conditions, install a 

normally closed 

door switch on the door and route 

two wires from the switch to the external controller.  Connect the door 
switch to the keypad’s SENSE terminal (E8) and ground terminal.  
(Either E1, E4, E5, or E7)
If an inhibit switch or timer is going to be used for temporarily 
disabling the keypad, route two wires from the switch or timer to the 
keypad box.  Connect the inhibit switch/timer 

normally open 

terminals 

to the keypad’s SENSE (E8) and ground (Either E1, E4, E5, or E7) 
terminal.

Request-to-Exit Input

(wiring shown Fig. 4)

If a request-to-exit pushbutton is going to be used, route two wires 
from the keypad box to a normally open pushbutton mounted on the 
secure side of the door.  Connect the wires to the pushbutton and to 
the keypad’s REX (E6) and COM (Either E1, E4, E5 or E7) terminals.

Solid State Outputs

The two solid state outputs (Outputs #3 & #4) can be programmed to 
activate during various conditions.  These outputs can be used to activate 
indicators or sounders.  See Fig. 5 for wiring examples using the solid 
state outputs.

6 wires for    

Keypad    

2 wires for

Power 

Supply

External Controller

2 wires for

Door Sensor

2 wires for

Strike Power

924P

Keypad

Summary of Contents for 924P EntryCheck

Page 1: ...shbutton to provide codeless activation of the Main Relay Auxiliary Relay Output 3 or Output 4 programmable The ALARM SHUNT signal is available when access is granted This signal can be programmed to...

Page 2: ...aster code Step 2 Enter 06 002 9876 9876 1 Present card Assign card to User 002 with a PIN code of 9876 Activate the main relay when validated Step 3 Repeat Step 2 to enter another unique user card or...

Page 3: ...KETED CABLE 100ft MAX RED BLK GRN GRY PINK BLU N C COM N O N C COM N O 1 GROUND C N O N C C N O N C N C DOOR POSITION SWITCH N O REQUEST TO EXIT SWITCH EARTH GROUND CONNECTION AUXILIARY OUTPUTS 100mA...

Page 4: ...door strike wire to the keypad s PWR terminal Connect a wire between the keypad s PWR terminal and the MAIN RELAY COM terminal Power Choose a location for the DC power supply or AC transformer Connect...

Page 5: ...rmined by the entry code length setting Leading zeros will have to be entered by the user when entering their code to gain access Erasing a Single User Press 02 User User User The user number to delet...

Page 6: ...REX input terminates toggle of Main Relay Main Relay On time Default 02 Seconds Sets the length of time the Main Relay activates when triggered Green LED is on when Main Relay is active Press 21 Secon...

Page 7: ...ault 02 Seconds Sets the length of time Output 3 activates when triggered Press 23 Seconds Seconds Output time in seconds 0 60 99 Toggle Mode Beep Sounds Anti Tamper Activation Default No Selects whet...

Page 8: ...ols INST 924 INST 924P vsd Rev C 10 14 Page 8 STANDARD WALL MOUNT SINGLE GANG BOX MOUNT OPTIONAL WALL MOUNT 3 413 CONTROLLER HOUSING MULLION MOUNT 1 375 7 3125 1 750 4X Mount at holes With supplied sc...

Reviews: