CAUTION

IF THE UNIT IS AC POWERED, MAKE SURE

THAT THE SECONDARY OF THE SYSTEM IS 

ISOLATED FROM EARTH GROUND

!

!

P:\INSTALLATION INST\Access Controls\INST-924\INST-924P.vsd     Rev C     10-14     Page 2

EXTERNAL CONTROLLER

Set default parameters (first time use)

Step 1. Enter:  

#9#  123456#

Enter the program mode (default master code)

Step 2. Enter: 

03#  4# 

Set the entry code length to 4 digits

Step 3. Enter:  

21# 5#

Set the main relay activation time for 5 sec.

Step 4. Enter:  

#  

Exit programming mode

**

Assign a user  (PIN only)

Step 1. Enter:  

#9#  123456#    

Enter programming mode (default master code)

Step 2. Enter:  

01#  003# 2580# 2580# 1#    

Assign User 003 with a PIN code of ‘2580’. 
Activate the main relay when entered.   

Step 3. Repeat Step 2 to enter another unique user & PIN or continue to Step 4.

Step 4. Enter:  

#  

Exit programming mode

**

Test your new user

Present your card or enter an authorized PIN code + #. The green indicator should 

illuminate and the main relay should activate, unlocking  the door for 5 seconds.

Assign a user  (Card & PIN only)

Step 1. Enter:  

#9#  123456#    

Enter programming mode (default master code)

Step 2. Enter:  

06#  002# 9876# 9876# 1# (Present card) 

Assign card to User 002 with a

PIN code of ‘9876’. Activate
the main relay when validated.

Step 3. Repeat Step 2 to enter another unique user & card, or continue to Step 4.

Step 4. Enter:  

#  

Exit programming mode.

**

Deleting a  user code

Step 1. Enter:  

#9#  123456#

Enter the program mode (default master code)

Step 2. Enter:  

02#  002# 002# 

User  2 has been deleted. 

Step 3. Enter:  

#  

Exit programming mode

**

QuickStart  Programming

You must first enter programming mode to perform any function. The yellow indicator will blink slowly showing that the  924P 
EntryCheck™ is in programming mode. Use the option codes to program each function.   After the new data entry is complete for 
each function , the yellow indicator will flash quickly while the data is being stored and the green indicator will light briefly if the 
programming has been accepted.  The red indicator will light if any programming data is entered incorrectly or the function is 
rejected. If a red indicator is seen, the entire function (option code + data)  will have to be fully re-entered.  The keypad will remain 
in programming mode until        # is pressed or after 30 seconds of inactivity.

**

RED/GREEN
POWER/ACCESS
INDICATOR

YELLOW
“PROGRAM 
MODE”
INDICATOR

KEYPAD

FRONT

Summary of Contents for 924P EntryCheck

Page 1: ...shbutton to provide codeless activation of the Main Relay Auxiliary Relay Output 3 or Output 4 programmable The ALARM SHUNT signal is available when access is granted This signal can be programmed to...

Page 2: ...aster code Step 2 Enter 06 002 9876 9876 1 Present card Assign card to User 002 with a PIN code of 9876 Activate the main relay when validated Step 3 Repeat Step 2 to enter another unique user card or...

Page 3: ...KETED CABLE 100ft MAX RED BLK GRN GRY PINK BLU N C COM N O N C COM N O 1 GROUND C N O N C C N O N C N C DOOR POSITION SWITCH N O REQUEST TO EXIT SWITCH EARTH GROUND CONNECTION AUXILIARY OUTPUTS 100mA...

Page 4: ...door strike wire to the keypad s PWR terminal Connect a wire between the keypad s PWR terminal and the MAIN RELAY COM terminal Power Choose a location for the DC power supply or AC transformer Connect...

Page 5: ...rmined by the entry code length setting Leading zeros will have to be entered by the user when entering their code to gain access Erasing a Single User Press 02 User User User The user number to delet...

Page 6: ...REX input terminates toggle of Main Relay Main Relay On time Default 02 Seconds Sets the length of time the Main Relay activates when triggered Green LED is on when Main Relay is active Press 21 Secon...

Page 7: ...ault 02 Seconds Sets the length of time Output 3 activates when triggered Press 23 Seconds Seconds Output time in seconds 0 60 99 Toggle Mode Beep Sounds Anti Tamper Activation Default No Selects whet...

Page 8: ...ols INST 924 INST 924P vsd Rev C 10 14 Page 8 STANDARD WALL MOUNT SINGLE GANG BOX MOUNT OPTIONAL WALL MOUNT 3 413 CONTROLLER HOUSING MULLION MOUNT 1 375 7 3125 1 750 4X Mount at holes With supplied sc...

Reviews: