FACTORY DEFAULTS

Master Programming CodeWWW..WWWWWWW.W.W...123456  
Entry Code LengthWWWWWWWWWWWWWWW.WW..4 digits
Entry  ModeWW..WWWWWWWWWWWWWW.W...Card or PIN
Request-to-exit Output RelayWWWWWWWWW...........No Output
Alarm Shunt OutputW.WWWWWWWWWWWWW.........Disabled
Forced Entry OutputWWWWWWWWWWW..WWWW..No Output
Door Ajar OutputWWWWWWWWWWWWW..WW.W...No Output
Main Relay On TimeWWWWWWWWWWWWW..W..02 Seconds
Auxiliary Relay On TimeWWWWWWWWWWW.....W02 Seconds
Solid State Output #3 On TimeWWWWWWWWW......02 Seconds
Solid State Output #4 On TimeWWWWWWWWWW..02 Seconds
Door Sense/Inhibit InputWWWWWWWWWW...WW..Door Sense
Keypad Lockout OutputWWWWWWWWWWWW..WW.Disabled
Keypad Active OutputWWWWWWWWWWWW..W..W..Disabled
Beeper Sounds When Key PressedWWWWWWWW...WWWYes
Beeper Sounds During Relay #1WWWWWWWWW..W...WW.No
Beeper Sounds During Relay #2WWWWWWWWWWW...W...No
Beeper Sounds During Output #3WWWWWWWWWWW   .....No
Beeper Sounds During Output #4WWWWWWWWWWW........No
Keypad Lockout CountWWW.WWW......W.3 Tries Before Lockout
Anti-Passback TimeWWWWWW..WW...WWW.No Anti-Passback
Auto-RelockWWWWWWWWWWWWW...WWWW.WWWW.On

Entering Programming Mode

The 6-digit Master Programming Code (default = 123456) is used 
to enter Programming Mode.

Press:  # 9 # Master Code #

Master Code = the current 6-digit Master Programming Code

Setting Entry Code Length

Default: 4 digits

Press: 03 # 

Length

#  

Length = 4-6 for entry code length

Note: 

If the Entry Code Length is going to be changed from the factory 

default of 4 digits, make this change first before programming any entry 
codes.

Adding a New User

User PIN Only Access (No Card)

Press: 01 # User # 

Code

Code # Relay #

---- Or ----

User Card and or  PIN Access

Press: 06 # User # 

Code

Code # Relay # Present Card

User

=User number to be added: 001-500  

Code

=The new entry code: 1-999999, depending on code length

Relay

=Relay output entry code will activate:

1=Main Relay   2=Auxiliary Relay   3=Both Relays
10=Relay #1, toggled  20=Relay #2, toggled  30=both Relays toggled
12=Relay #1 toggled; Relay #2 timed open
21=Relay #1 timed open; Relay #2 toggled

The yellow indicator will flash quickly while the 924P stores the new 
user information in memory  The green indicator will light when the 
new code and card are accepted. If the user number already exists 
or an entry error has been made, the red indicator will light.  Delete 
the user and re-enter the new information again.

Note:

Leading zeros (zeros before the code number, i.e.0001) do not need to 

be entered when programming a new code.  The 924P will internally add any 
zeros to fill digits determined by the entry code length setting.  Leading zeros 
will have to be entered by the user when entering their code to gain access.

Erasing a Single User

Press: 02 # 

User

#  

User

#  

User =The user number to delete  002-500

The yellow indicator will flash quickly while the 924P erases the 
user from  memory.  The green indicator will light when the code is 
erased.

Exiting Programming Mode

Press:        # 

The red indicator will light after exiting Programming Mode

Note: 

The 924P will automatically exit Programming Mode after 

two minutes of inactivity

**

Re-entering a Command After a Mistake

If the red indicator lights, signaling an incorrect entry, or an 
incorrect key is pressed during programming, to clear the keypad 
and re-enter the command:

Press:      9 #  

*

Select Entry Mode

Default:  Card or PIN

Sets the entry mode for the 924P.

Press:  05 # Mode #

Mode=Operating Mode(1-3)

1=Card or PIN;  2=Card Only  3=Card and PIN

P:\INSTALLATION INST\Access Controls\INST-924\INST-924P.vsd     Rev C     10-14     Page 5

BASIC PROGRAMMING

When the 924P EntryCheck™ is in Programming Mode the yellow 
indicator will blink slowly.  After a programming command is 
selected, the yellow indicator will flash rapidly while the keypad is 
waiting for user input data.  The green indicator will light if the data 
is accepted.  The red indicator will light if any programming data is 
entered incorrectly, and the command will have to be fully re-
entered.     

Output Toggle Mode

When an output is programmed for Toggle Mode, the output 
alternates from OFF to ON or from ON to OFF each time it is 
accessed.  When an output is toggled on, the green LED remains 
solid until toggled off.

The rules for a toggle output are:

If the output is OFF, it will turn ON and stay on until the next 
activation.
If the output is ON, it will turn OFF and stay off until the next 
activation.
An authorized PIN, Card, or REX input programmed to 
momentarily activate that same relay will reset the relay to its 
normal state.

Adding  Multiple Sequential Cards

Press: 08 # 1

st

User

# Code # Code # Relay # Number of users

# Present 1

st

card 

1

st

User =Starting user number to add

Number of users = Total number of consecutive cards  to add

The yellow indicator will flash quickly while the 924P erases the 
user from  memory.  The green indicator will light when the codes 
have been  added.

Adding  Multiple Non-Sequential Cards

Press: 07 # 1

st

User

# Code # Code # Relay # Number of users

# Present 1

st

card, Present 2

nd

card, G, Present last card 

1

st

User =Starting user number to add

Number of users = Total number of consecutive cards  to add

The yellow indicator will flash quickly while the 924P erases the 
user from  memory.  The green indicator will light when the codes 
have been  added.

Summary of Contents for 924P EntryCheck

Page 1: ...shbutton to provide codeless activation of the Main Relay Auxiliary Relay Output 3 or Output 4 programmable The ALARM SHUNT signal is available when access is granted This signal can be programmed to...

Page 2: ...aster code Step 2 Enter 06 002 9876 9876 1 Present card Assign card to User 002 with a PIN code of 9876 Activate the main relay when validated Step 3 Repeat Step 2 to enter another unique user card or...

Page 3: ...KETED CABLE 100ft MAX RED BLK GRN GRY PINK BLU N C COM N O N C COM N O 1 GROUND C N O N C C N O N C N C DOOR POSITION SWITCH N O REQUEST TO EXIT SWITCH EARTH GROUND CONNECTION AUXILIARY OUTPUTS 100mA...

Page 4: ...door strike wire to the keypad s PWR terminal Connect a wire between the keypad s PWR terminal and the MAIN RELAY COM terminal Power Choose a location for the DC power supply or AC transformer Connect...

Page 5: ...rmined by the entry code length setting Leading zeros will have to be entered by the user when entering their code to gain access Erasing a Single User Press 02 User User User The user number to delet...

Page 6: ...REX input terminates toggle of Main Relay Main Relay On time Default 02 Seconds Sets the length of time the Main Relay activates when triggered Green LED is on when Main Relay is active Press 21 Secon...

Page 7: ...ault 02 Seconds Sets the length of time Output 3 activates when triggered Press 23 Seconds Seconds Output time in seconds 0 60 99 Toggle Mode Beep Sounds Anti Tamper Activation Default No Selects whet...

Page 8: ...ols INST 924 INST 924P vsd Rev C 10 14 Page 8 STANDARD WALL MOUNT SINGLE GANG BOX MOUNT OPTIONAL WALL MOUNT 3 413 CONTROLLER HOUSING MULLION MOUNT 1 375 7 3125 1 750 4X Mount at holes With supplied sc...

Reviews: