CAUTION

IF THE UNIT IS AC POWERED, MAKE SURE

THAT THE SECONDARY OF THE SYSTEM IS 

ISOLATED FROM EARTH GROUND

!

!

Fig. 2 Typical Wiring

(8) SENSE

(7) GROUND

(6) REQUEST TO EXIT

(5) GROUND

(4) GROUND

(3) OUTPUT 3

(2) OUTPUT 4

KEY PAD POWER

12-24 VOLTS

AC OR DC

AUXILIARY RELAY

2 AMPS @ 28VDC MAX

}

FAIL SAFE

MAIN RELAY

5 AMPS @ 28VDC MAX

12v or 24v 

Power Supply

DTRX

POWER

+

-

6   5   4   3   2   1

2   1

1   2   3 1   2   3 1   2   3   4   5   6   7   8

MAIN

AUX

WIRES

JP2

POWER

LED

KEYPAD

BACK

DTRX

PIGTAIL

USER PROVIDED  

6 CONDUCTOR

JACKETED CABLE

(100ft MAX)

R

E

D

B

L

K

G

R

N

G

R

Y

P

IN

K

B

L

U

N/C

COM

N/O

N/C

COM

N/O

+

-

(1) GROUND

C

N/O

N/C

C

N/O

N/C

N/C DOOR 

POSITION

SWITCH

N/O 

REQUEST-

TO-EXIT
SWITCH

EARTH 

GROUND 

CONNECTION

AUXILIARY OUTPUTS

100mA MAX TO COMMON

FAIL SECURE

COMMON

}

MASTER CODE
RESET JUMPER
(JP2)

P:\INSTALLATION INST\Access Controls\INST-924\INST-924P.vsd     Rev C     10-14     Page 3

KEYPAD

WIRE
HARNESS

ANTI-TAMPER

SWITCH

BACK

JP1

FRONT

RED/GREEN
POWER/ACCESS
INDICATOR

YELLOW
“PROGRAM 
MODE”
INDICATOR

KEYPAD

KEYPAD
POWER

ACCESSORY

TERMINALS

(E1-E8)

MAIN

RELAY

AUXILIARY

RELAY

MASTER CODE
RESET JUMPER
(JP2)

EXTERNAL 

BOARD

DTRX

POWER

+

-

6   5   4   3   2   1

2   1

1   2   3 1   2   3 1   2   3   4   5   6   7   8

MAIN

AUX

WIRES

JP2

POWER

LED

DTRX PIGTAIL

}

Summary of Contents for 924P EntryCheck

Page 1: ...shbutton to provide codeless activation of the Main Relay Auxiliary Relay Output 3 or Output 4 programmable The ALARM SHUNT signal is available when access is granted This signal can be programmed to...

Page 2: ...aster code Step 2 Enter 06 002 9876 9876 1 Present card Assign card to User 002 with a PIN code of 9876 Activate the main relay when validated Step 3 Repeat Step 2 to enter another unique user card or...

Page 3: ...KETED CABLE 100ft MAX RED BLK GRN GRY PINK BLU N C COM N O N C COM N O 1 GROUND C N O N C C N O N C N C DOOR POSITION SWITCH N O REQUEST TO EXIT SWITCH EARTH GROUND CONNECTION AUXILIARY OUTPUTS 100mA...

Page 4: ...door strike wire to the keypad s PWR terminal Connect a wire between the keypad s PWR terminal and the MAIN RELAY COM terminal Power Choose a location for the DC power supply or AC transformer Connect...

Page 5: ...rmined by the entry code length setting Leading zeros will have to be entered by the user when entering their code to gain access Erasing a Single User Press 02 User User User The user number to delet...

Page 6: ...REX input terminates toggle of Main Relay Main Relay On time Default 02 Seconds Sets the length of time the Main Relay activates when triggered Green LED is on when Main Relay is active Press 21 Secon...

Page 7: ...ault 02 Seconds Sets the length of time Output 3 activates when triggered Press 23 Seconds Seconds Output time in seconds 0 60 99 Toggle Mode Beep Sounds Anti Tamper Activation Default No Selects whet...

Page 8: ...ols INST 924 INST 924P vsd Rev C 10 14 Page 8 STANDARD WALL MOUNT SINGLE GANG BOX MOUNT OPTIONAL WALL MOUNT 3 413 CONTROLLER HOUSING MULLION MOUNT 1 375 7 3125 1 750 4X Mount at holes With supplied sc...

Reviews: