background image

Beep Sounds During Auxiliary Relay

Default: No

Selects whether or not the keypad beeps during Auxiliary Relay 
activation.

Press: 42 # 

Sound

#  

Sound=1 for Yes, =0 for No

Beep Sounds During Output #3

Default: No

Selects whether or not the keypad beeps during Output #3 
activation.

Press: 43 # 

Sound

#  

Sound=1 for Yes, =0 for No

Beep Sounds During Output #4 

Default: No

Selects whether or not the keypad beeps during Output #4 
activation.

Press: 44 # 

Sound

#  

Sound=1 for Yes, =0 for No

Keypad Lockout Count

Default: 3 Attempts

Sets the number or incorrect entry code attempts allowed 
before the keypad “locks out” for 60 seconds.

Press: 50 # Attempts #  

Attempts=Number of attempts before lockout (2-7)

Anti-Pass Back Time

Default: No Anti-Pass Back

Sets the length of time an entry code will not function after it is 
used.

Press: 51 # Minutes #  

Minutes=Time in minutes (2-4), 0=No Anti-passback

Beep Sounds During Main Relay

Default:  No

Selects whether or not the keypad beeps during Main Relay 
activation.

Press: 41 # 

Sound

#  

Sound=1 for Yes, =0 for No

Solid-state Output #4 On-time

Default:  02 Seconds

Sets the length of time Output #4 activates when triggered.

Press: 24 # 

Seconds

#  

Seconds=Output time in seconds (0-60), 99=Toggle Mode

Beep Sounds on Keystrokes

Default:  Yes

Selects whether or not the keypad beeps as each key is pressed.

Press: 40 # 

Sound

#  

Sound=1 for Yes, =0 for No

Selects mode for Keypad LED Backlight

Default: 30 Seconds

Selects whether or not the keypad back light stays OFF, lights for 30 
seconds when activated or stays ON.

Press: 52 # Output #  

0 = Light always OFF

1 = 30 sec light when activated (default)

2 = Light always ON 

Solid-state Output #3 On-time

Default:  02 Seconds

Sets the length of time Output #3 activates when triggered.

Press: 23 # 

Seconds

#  

Seconds=Output time in seconds (0-60), 99=Toggle Mode

Beep Sounds Anti-Tamper Activation 

Default: No

Selects whether or not the keypad beeps during Anti-Tamper 
switch activation.

Press: 45 # 

Sound

#  

Sound=1 for Yes, =0 for No

Changing the Beeper Sound Level

The Keypad’s beeper can be set to high or low level.
Remove jumper JP1 to reduce beeper sound level.

Changing the 6-Digit Master Programming Code

Press: 98 # 

Master Code

Master Code

#  

Master Code=The new 6-digit Master Programming Code

P:\INSTALLATION INST\Access Controls\INST-924\INST-924P.vsd     Rev C     10-14     Page 7

RESETTING KEYPAD

Master Reset

CAUTION:  Performing a master reset will clear the 
entire memory of the 924P and return all programmable 
options to the factory default values.  ALL ENTRY 
CODES WILL BE ERASED. NOTE:  The Master Code will 
NOT be reset.

STEP 1

Disconnect power from the 924P controller.

STEP 2

Press and hold down the * and # keys on the keypad.

STEP 3

Reconnect the controller power, continue holding the 
keys down until the red indicator starts flashing.

STEP 4

Release the keys.  The red and yellow indicators will 
remain lit until the process is complete, then the 
yellow indicator will go out.

Resetting the Master Code

STEP 1

Remove the cover from the 924P controller box and 
disconnect power.

STEP 2 

Locate & Remove jumper at JP2.  Reference page 3.  

STEP 3

Re-apply power.  You will get a single beep and 
the yellow LED on the keypad will flash momentarily.

STEP 4

Replace jumper on JP2.

THE MASTER PROGRAMMING CODE IS NOW 123456.

Door Ajar Timer

Default:  60 Seconds

Sets the amount of time the door may be held open after an 
authorized access.  The DOOR AJAR output will activate after the 
time expires.

Press: 25 # 

Seconds

#  

Seconds=Held open time in seconds (1-60)

Summary of Contents for 924P EntryCheck

Page 1: ...shbutton to provide codeless activation of the Main Relay Auxiliary Relay Output 3 or Output 4 programmable The ALARM SHUNT signal is available when access is granted This signal can be programmed to...

Page 2: ...aster code Step 2 Enter 06 002 9876 9876 1 Present card Assign card to User 002 with a PIN code of 9876 Activate the main relay when validated Step 3 Repeat Step 2 to enter another unique user card or...

Page 3: ...KETED CABLE 100ft MAX RED BLK GRN GRY PINK BLU N C COM N O N C COM N O 1 GROUND C N O N C C N O N C N C DOOR POSITION SWITCH N O REQUEST TO EXIT SWITCH EARTH GROUND CONNECTION AUXILIARY OUTPUTS 100mA...

Page 4: ...door strike wire to the keypad s PWR terminal Connect a wire between the keypad s PWR terminal and the MAIN RELAY COM terminal Power Choose a location for the DC power supply or AC transformer Connect...

Page 5: ...rmined by the entry code length setting Leading zeros will have to be entered by the user when entering their code to gain access Erasing a Single User Press 02 User User User The user number to delet...

Page 6: ...REX input terminates toggle of Main Relay Main Relay On time Default 02 Seconds Sets the length of time the Main Relay activates when triggered Green LED is on when Main Relay is active Press 21 Secon...

Page 7: ...ault 02 Seconds Sets the length of time Output 3 activates when triggered Press 23 Seconds Seconds Output time in seconds 0 60 99 Toggle Mode Beep Sounds Anti Tamper Activation Default No Selects whet...

Page 8: ...ols INST 924 INST 924P vsd Rev C 10 14 Page 8 STANDARD WALL MOUNT SINGLE GANG BOX MOUNT OPTIONAL WALL MOUNT 3 413 CONTROLLER HOUSING MULLION MOUNT 1 375 7 3125 1 750 4X Mount at holes With supplied sc...

Reviews: