OPERATING GUIDE for your

 

GEM-K1CA KEYPAD 

© NAPCO 2005 

ARM

ED

 

COMP UT ERIZED SE CURITY  SYSTEM 

STA

TUS

 

G E M IN I 

 

R

  1   2   3  

 

B   4   5   6  

 

C   7   8   9   0  

 

 

 

SYSTEM READY 
09/15/05   12:05 AM 

NEXT / YES 

PRIOR / NO 

AREA 

OI279D  5/05 

Summary of Contents for Gemini GEM-K1CA

Page 1: ...OPERATING GUIDE for your GEM K1CA KEYPAD NAPCO 2005 ARMED COMPUTERIZED SECURITY SYSTEM STATUS GEMINI R 1 2 3 B 4 5 6 C 7 8 9 0 P Q G U SYSTEM READY 09 15 05 12 05 AM NEXT YES PRIOR NO AREA OI279D 5 0...

Page 2: ...f readiness by testing it at least once a week in both the ac battery and battery only modes ask your alarm professional how to make these tests INTRODUCTION IMPORTANT TEST YOUR SYSTEM WEEKLY Test you...

Page 3: ...ELL PHONE STYLE 24 SETTING THE DATE AND TIME 26 KEYPAD MESSAGES 27 GLOSSARY 30 SYSTEM TROUBLE ERROR CODES 33 TROUBLESHOOTING 38 TO SILENCE AN ALARM ENTER YOUR CODE AND PRESS U FOR SERVICE CALL _______...

Page 4: ...4 KEYPAD CONTROLS INDICATORS ARMED COMPUTERIZED SECURITY SYSTEM STATUS GEMINI R 1 2 3 B 4 5 6 C 7 8 9 0 P Q G U SYSTEM ARMED 09 01 05 12 00 AM 1 2 3 4 5 6 7 12 8 9 10 11...

Page 5: ...tors Numerical Keys 1 9 0 Used to enter codes zone numbers etc ENTER Button Entry key Causes the entered code or selected function to be executed STAY Button 1 Bypasses all Interior Zones simultaneous...

Page 6: ...ining in 10 second steps Note If you enter a wrong code the keypad will display INVALID ENTRY TRY AGAIN 3 Leave the premises Leave through the exit door before exit time expires Priority Arming If you...

Page 7: ...arm disarm a different area 1 Press the numerical key representing the other area number 2 Press Gfollowed by U The keypad will now provide status and control of that area 3 Enter your User Code foll...

Page 8: ...instant protection press and hold down P for 2 seconds at any time after the system is armed When armed with Instant Protection opening the entry door will cause an immediate alarm When arming with In...

Page 9: ...awaking the family Press U to activate Easy Exit on your system GEM P3200 GEM P9600 V20 or greater GEM P816 P1632 V9A or greater Emergency Buttons Only available if programmed The Blue Emergency Butto...

Page 10: ...s disarmed the window will continue to display ALARM followed by the zone s violated 2 To reset the display note the zones violated then press C Ambush Optional Your Ambush Code Type is TYPE 1 Prefix...

Page 11: ...a smoke detector tripped its red alarm indicator light will be on After the alarm condition is corrected thermostat cooled down smoke cleared from detector etc pressing C again will reset the keypad w...

Page 12: ...th all those who use the building 1 In a residence sleep with the bedroom door closed A closed door will hold back deadly smoke while you escape 2 When the fire alarm signals escape quickly Do not sto...

Page 13: ...13 FIRE PROTECTION Floorplan Draw a plan of your premises in the space provided below Floorplan...

Page 14: ...es because the fire may be a slow smoldering low heat type producing smoke because they may not be near the fire or because the heat of the fire may bypass them These detectors will not detect oxygen...

Page 15: ...d for longer than one minute Display Zone Faults Displays the zone number of zones that are not secured If needed press the NEXT and PRIOR Buttons as displayed on screen to scroll faulted zones requir...

Page 16: ...ys trouble conditions that have been detected on the Fire Zone s Use NEXT P and PRIOR Q to scroll zones required for GEM P3200 9600 panels GEM P816 1632 panels will auto scroll Activate Chime The Chim...

Page 17: ...he Function Menu scroll to RESET SENSOR MSG and press U If you cannot correct the problem call for service Note This function available with GEM P9600 and GEM P3200 control panels only Start Exit Time...

Page 18: ...4 hours To Delay Arm the system With the function TO ARM IN 1 4 HRS displayed in the window enter the desired Delay Arming time in hours 1 2 3 or 4 followed by U At the end of this 1 4 hour Delay Armi...

Page 19: ...o the next group or PRIOR Q to scroll back to the previous group Press C when done Note This function available with GEM P9600 and GEM P3200 control panels only Relay Group 01 ________________________...

Page 20: ...to 45 sec onds at your option by consulting with your installer Regular Burglary Non 24 Hour Zone reports are aborted by disarming within the delay period 24 Hour Zones and zones programmed to report...

Page 21: ...tral station acknowledges receipt ringback exit delay will start If ringback is not heard within about 30 seconds a communication problem may exist call for service Function 11 Start Exit Time may the...

Page 22: ...when U is pressed Repeat Steps 1 through 3 for each User Code to be programmed Erasing a User Code 1 Enter the digits of the user number to be erased followed by RR 2 Press G0 to erase each digit of...

Page 23: ...panel enter all three digits of the user number 4 Press U to save the code Note Duplicate Codes are not allowed therefore a duplicate Code entered in the LCD Window will erase when U is pressed Press...

Page 24: ...he next zone or to any other zone Move the cursor to the displayed zone number i e 01 using R and B Change the zone number using keys 0 through 9 Enter two digits for the zone number after entering th...

Page 25: ...UENCE 1 ABC1 1 abc1 2 DEF2 2 def2 3 GHI3 3 ghi3 4 JKL4 4 jkl4 5 MNO5 5 mno5 6 PQR6 6 pqr6 7 STU7 7 stu7 8 VWX8 8 vwx8 9 YZ90 9 yz90 0 SPACE 0 Reserved CELL PHONE STYLE ENTRY Use R and B buttons to mov...

Page 26: ...enter 07 29 00 2 Press U to save the Date Programming the Time After entering in the Date press NEXT P for the Time Entry screen 1 At the Enter Time screen simply punch in the correct time using the n...

Page 27: ...dicates Service Code active I indicates arming with Instant protection Entry delay in progress XXX shows entry time remaining in seconds System armed With the GEM P3200 9600 panels the I indicates arm...

Page 28: ...ess C to silence sounder Evacuate premises or correct cause of alarm For partitioned systems only Code not valid for area Wrong code entered or Easy Bypass function not enabled In Manager s Mode Armin...

Page 29: ...receives an acknowledgment from the central station of the cancellation of the alarm signal Indicates problem s detected on system See examples below and SYSTEM TROUBLE ERROR CODES for a complete list...

Page 30: ...by its own keypad or by a keypad of a different Area through Managers Mode Arming Disarming Turning the system on off by entering your code at the keypad then pressing U Battery Backup power source in...

Page 31: ...ort Delay see Abort Delay Report A transmission to a central station notifying of a change in the status of the system alarm trouble low battery etc RF Low Battery Wireless sys tems only Weak transmit...

Page 32: ...elay only occurs if re entry takes place through the normal exit entry door first Fire Zone Detects fire alarms or trouble conditions Interior Zones Circuits within the premises usually including spac...

Page 33: ...System Trouble Condition Action E01 00 AC Power Failure This trouble will occur if AC power is not present Make sure system transformer is plugged into AC receptacle and check the circuit breaker oth...

Page 34: ...equired for the GEM PIR and GEM GB The replacement battery for the GEM SMK is the Duracell MN1604 9 Volt Alkaline 2 required The GEM DT Dual Technology Sensor requires 4 C cell alkaline batteries Warn...

Page 35: ...e Fail ure NN Relay Board Number Call installing company for service E15 NN RF Transmitter Tamper Wireless Transmitter Tamper Cover removed NN Transmitter Number Call installing company for service E1...

Page 36: ...the sensor is able to detect activity in the area clear any obstacles which may be blocking the sensor from detecting activity Press C to clear the display and then use the Function Menu to Reset Sens...

Page 37: ...re zone indicated Call installing company for service GEM P1632 and GEM P816 panels only E51 00 Bell Siren Trouble There is a problem with the Bell or Siren Call installing company for service E58 00...

Page 38: ...the scrolling error codes which represent the trouble Press C and you will now be able arm to the system but the trouble must be fixed as soon as possible See Page 7 33 The Fire Alarm is sounding and...

Page 39: ...39 NOTES...

Page 40: ...any or all of the following criminal tampering electrical or communications disruption it is possible for the system to fail to perform as expected NAPCO does not represent that the product system ma...