INBUILT INTO ISLAND WALL
STEP 17: HEARTH (FLOOR PROTECTOR)
The hearth must be constructed from masonry or a non
combustible material, and must extend 500mm or 600mm in
front of any part of the appliance, 250mm on either side and a
thickness of 75mm.
STEP 16: VENTILATION
**IMPORTANT**
Ventilation is required on the enclosure to help with air
circulation. A minimum of two air intake grills are required
at the bottom and a minimum of two air out-take grills are
required on top of the masonry enclosure (2X inflow 2X
outflow). All vents can be positioned either side OR the front of
the masonry enclosure. ALL vents must adhere to the minimum
vent size of 600cm
2
.
Minimum vent sizes are 100mm x 300mm with a minimum
quantity of four*
*The vent sizes and quantity can be adapted and changed
BUT they must meet the minimum ventilation requirements
as specified above. For custom made vents please contact
your nearest dealer. ALL VENTS MUST NOT BE PLASTIC OR
COMBUSTIBLE.
*All air vents must have a minimum clearance to combustibles
of 600mm in front and 500mm above the metal vent itself.
STEP 18: BAFFLE PLATE
Ensure the baffle plate sits securely in place, this step is
vitally important for the safe use and proper functioning of the