SPECIFICATIONS
MEChANICAL TROUBLEShOOTINg
80
SCIFIT Scientific Solutions For Fitness SCIFIT Scientific Solutions For Fitness SCIFIT
Step One Mechanical Troubleshooting
1. Clunking noise and rod end links seem to be loose.
a. Torque all link bolts to 720 in/lbs (60 ft/lbs).
2. Squeaking at high resistance coming from belts.
a
. C lean pedal belt pulleys a nd pe dal belts of a ny oi l. This c an a lso
be done if the pedal seems to be slipping on the way down.
3. Indexing handle spins 360 degrees and does not stop at +/- 30 degrees.
a. Adjust the set screw on the outer handle up one revolution.
Symptom:
1. Clunking noise and rod end links seem to be loose.
2. Squeaking at high resistance coming from belts.
3. Indexing handle spins 360 degrees and does not stop at +/- 30 degrees.