![SCIFIT STEP ONE Service Manual Download Page 32](http://html.mh-extra.com/html/scifit/step-one/step-one_service-manual_1217587032.webp)
SPECIFICATIONS
MEChANICAL PARTS REMOVAL/REPLACEMENT
Step 6:
3/8” Allen Hex
5/8” Socket
Tor
que W
rench
Secure the hardware of the upper pivot link
to the pivot blade using a 3/8” allen hex
and a torque wrench set at 720 in/lbs with
a 5/8” socket attached.
Step 7:
Repeat step 6 for the right pivot link.
29
SCIFIT Scientific Solutions For Fitness SCIFIT Scientific Solutions For Fitness SCIFIT
SPECIFICATIONS
LoWEr/UppEr covEr rEmovAL
*Phillips screwdriver *Ratchet * 1/2” Socket
Tools Required:
1/2” Socket
Screw locations
Use a 1/2” socket to remove the two
5/16-18 x 1/2” flange bolts (#19651) that
secure the console bracket to the frame.