7.2 Transverse cleaning
43
7.2 Transverse cleaning
Table 7.2 Transverse cleaning - measures at faults
No transverse cleaning
Error
Cause
Remedies
No power
- motor protection tripped
- check cause (E)
- control defective
- check (E)
- connections
- check (E)
- brush motor defective
- check (E)
Drive
- carriage bearing defective
- repair
- motor defective
- check motor (E)
- drive chain defective
- check, repair
- tappet screws defective
- replace
- control defective
- check (E)
- connections
- check (E)
- frequency converter
- check (E)
- PLC
- check (Schwarz GmbH)
Transverse
cleaning
sensors
- defective
- replace and readjust
- incorrect setting
- see "Setting up the transverse clean-
ing sensors"
Brush
- retention nut loose
- tighten
- tappet piece on shaft is miss-
ing
- check, insert if required
Transverse cleaning too strong or too weak
Error
Cause
Remedies
Transverse
cleaning
sensors
- sensor misadjusted
- see "Setting up the transverse clean-
ing sensors"
- defective
- check (E)
- PLC
- check (Schwarz GmbH)
- supply via screen
- correct
Drive
- PLC
- check (Schwarz GmbH)
- roller carriage bearing
- check, replace if required
- frequency converter
- check (E)
Brush
- worn
- replace
Summary of Contents for SB10B
Page 48: ...48 8 Spare parts and circuit diagrams Figure 8 2 Overview spare parts page 2...
Page 49: ...8 1 Overview drawings 49 Figure 8 3 Overview spare parts page 3...
Page 50: ...50 8 Spare parts and circuit diagrams Figure 8 4 Overview spare parts page 4...
Page 51: ...8 1 Overview drawings 51 Figure 8 5 Overview spare parts page 5...
Page 52: ...52 8 Spare parts and circuit diagrams Figure 8 6 Overview spare parts page 6...
Page 53: ...8 1 Overview drawings 53 Figure 8 7 Overview spare parts page 7...
Page 88: ......
Page 90: ...90 10 EC declaration of conformity...
Page 91: ...10 1 EC declaration of conformity 91 11 Annex third party documentation See supplements...
Page 95: ...12 1 Notes 95...
Page 96: ...96 12 Notes...