Check for water leaks 

Summary of Contents for SC80

Page 1: ...SC80 Installation User guide ...

Page 2: ...ter replacement Page 6 CO2 bottle replacement Page 7 CO2 adjustment Page 8 Water temp adjustment Page 9 Component checklist Page 10 Install layout Page 11 Ventilation requirements Page 13 Instillation guide Page 23 Unit setup Page 29 Warranty Page 30 Unit shut down Page 31 Service ...

Page 3: ... or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance This appliance is intended for use in household and similar applications such as light commercial up to 8 staff the hospitality industry and related resid...

Page 4: ...nit has slow or no cold water Filter needs changing water supply is blocked or there is not enough water pressure Replace filter if still slow shut down unit and Call MERQUIP Sparkling water has little or no fizz CO2 bottle empty CO2 pressure below 3 Bar or the water temp is too high Adjust CO2 pressure check water outlet temp is below 10degC then replace CO2 bottle if fault not fixed shut down un...

Page 5: ...e ON Leave water supply ON Filter has auto shutoff valve To ensure your Schwan drinking water system continues to provide you with fresh filtered chilled and sparkling drinking water your Schwan filter cartridge needs to be replaced at least every 12 months In some situations where there is a lot of sedimentation or chemicals in the water supply it may be advisable for the filters to be replaced m...

Page 6: ...de of tap until sparkling water starts to flow leave running for 10 sec then shut off Open regulator by turning knob clockwise Adjust CO2 pressure using control knob to 4 bar Change CO2 canister when pressure can t be adjusted over 2 bar 1 3 4 5 6 7 8 9 10 Leave CO2 to settle for 1 2 hour then adjust using instructions on next page OFF Shut gas off at regulator using control knob turn off gas by t...

Page 7: ...tch gauge on regulator and make sure the pressure doesn t ex ceed 5 Bar We recommend not having the unit under 3 Bar as the unit will not produce enough sparkle 3 5 Bar 3 5 Bar Pressure UP Pressure DOWN After adjusting pressure run tap until pump starts then re adjust pressure continue process until right setting achieved Pressure must not exceed 5 bar ...

Page 8: ...MAX chill could cause it to ice up use MAX setting at own risk Water temp effects the carbonation of the sparkling water the warmer the water the less fizz the water will hold The overall best setting to have chiller on is setting 6 NOTE Use flat blade screw driver to adjust water temp ...

Page 9: ...etal washer 7 chiller unit 8 Filter with filter head 9 Filter bracket 10 chiller 3 pin plug 21 Soda regulator 11 CO2 regulator packed in separate box 13 JG reducer 8 6mm 14 JG flow bend support 15 stop tap connector 1 4 inch tube 16 PRV 17 8mm JG plug 18 6mm co2 tube 19 1 4 inch water supply tube 20 20mm screws x 9 ...

Page 10: ...ations where any water leakage could result in damage to property the complete Schwan installation should be installed over a Drained Safe Tray plumbed to an appropriate drainage connection WARNING NOTE Allow a minimum of 100mm air space around the sides back and the front of the chiller Cabinet must be vented to provide air flow see venting diagram on next page The filter system and CO2 bottle mu...

Page 11: ...an 200mm from the top There must be a 100mm air space on both sides of the under bench chiller The front of the unit must have at least 100mm of air space The back of the unit needs 100mm of clearance for tubing The amount of air space around the unit apply for both passive and fan forced ventilation ...

Page 12: ...et must be at least 200mm x 40mm The measurements given are the minimum sizes required to provide sufficient air flow to cool the compressor any less air flow and the units capacity will be effected If there is not enough room to place the right size vents or the cabinet temp is reaching over 27o C the cabinet will need to be vented using a fan forced system to provide enough air flow WARNING Venting re...

Page 13: ...13 Installation ...

Page 14: ... to a surface of more than 30mm thick There must be a 50mm diameter flat and solid clamping surface under the bench for the tap mounting system The centre of the hole must be no further than 80 mm from sink Place tap base with washer over the hole in the bench Make sure bench top is flat Tap install 1 2 3 ...

Page 15: ...tom of dispenser Slide dispenser with tubes and mounting rod into hole and sit on tap base Thread washers onto rod rubber first then metal followed by nut Using 13 mm tap spanner tighten nut so tap is firmly mounted on bench 4 5 6 7 ...

Page 16: ...fully into connector Fit PRV with arrow pointing way of flow con nect blue tube coming from supply to the inlet of the Valve and connect a length of tube to the outlet Fasten clip to wall using one screw and clip PRV into place Fit bracket to filter head using 4 screws take note of the IN and OUT on the head attach bracket the appropriate way around depending on which side of the chiller the filte...

Page 17: ...ply tube from PRV to inlet of filter head NOTE make sure that the tube is going into the IN side of the filter head Fit rest of blue 1 4 inch tube to filter outlet Do not trim tube to length All tubing must be cut square and clean to fit into fittings 5 6 ...

Page 18: ...ANCE 100MM CLEARANCE 100MM CLEARANCE 100MM CLEARANCE Unit air space clearance requirements Remove ice bank plug from back of unit Use supply tube from filter to fill ice bank Fit tube with 8mm adapter into fill ice bank inlet 1 2 3 ...

Page 19: ...ially to provide a slow flow do not turn on fully Fill ice bank to point shown between min and max level When ice bank is full turn off water supply Unplug fitting from ice bank NOTE some water will spill out 4 5 6 7 ON OFF ...

Page 20: ...20 Put Red ice bank plug back in to ice bank inlet Fit water supply fitting into WATER IN Attach flow bend clip to tube as shown Plug in power cord to back of unit 8 9 10 11 ...

Page 21: ...er The tubes coming from the tap attach to the soda out white and water out blue trim to length Max distance from tap to chiller is 700mm Measure distance and trim tubes 100mm longer Attach CO2 regulator to CO2 bottle and screw up by hand until sealed Note if gas starts coming out of regulator once bottle is sealed turn knob anticlockwise until flow stops Fit 6mm black tube to fitting on CO2 regul...

Page 22: ...h to provide continuous fall but aren t under strain Right length Too long Too short Position gas bottle and trim tube to length Fit other end of tube to CO2 IN on the Chiller Plug in 3 pin plug to power supply Do not turn on yet Tube length check 15 16 17 ...

Page 23: ...23 Initial setup ...

Page 24: ...Open cold lever on dispenser Open cold water supply slowly until fully open Run cold water for 5 min to clear any air bubbles and check for leaks at points shown on next page Setting up water supply 1 2 3 ...

Page 25: ...25 Check for water leaks 4 ...

Page 26: ... 5 min then shut it off NOTE the water on this side will come out slow until gas is applied ON Turn power on at the wall Socket Turn power on at the unit The switch will light up when power is turned on Turn on chiller and rotate chiller temp adjuster using flat bladed screw driver to setting 6 5 6 7 8 ON ...

Page 27: ...lator and set to 4 bar NOTE CO2 must not exceed 5 bar 4 Bar 1 2 3 4 5 6 7 Open soda leaver on tap 1 2 way water will gush out open for 10 seconds Shut off and the CO2 pump should start up Check for gas leaks 9 10 11 12 ...

Page 28: ...28 Installed unit should look like this ...

Page 29: ... associated costs Alternatively Schwan may require you to return your unit to Schwan so that Schwan can provide you with a replace ment unit free of charge In this case Schwan will pay the necessary freight charges and you will need to take re sponsibility for the removal of the faulty unit and installation of the replacement unit Any product replaced or repaired under this Warranty will be covere...

Page 30: ... min 4 OFF Turn power off at the wall 2 Turn off water supply at stop tap 5 6 7 Open cold tap until water stops flowing Leave sparkling side of tap open Unit shutdown To restart unit follow steps in reverse OFF Shut gas off at regulator using control knob turn off gas by tuning knob anticlockwise until it is at full off position 1 ...

Page 31: ...31 For service call 0800 636 0 636 Or visit www merquip co nz And book a service This unit is backed by MERQUIP NOTES ...