4
Fault
Cause
Action
Chiller system will not start
No power / water or faulty chiller unit
Check power and water supply is on,
if so then shut down unit
Call MERQUIP
Unit chilling full time and producing
cold water
Ventilation below min requirements.
The unit is running at MAX capacity.
Increase cabinet ventilation make
sure the chill temp is not on MAX. if
still faulting shut down unit and Call
MERQUIP
Unit Chilling full time but water is not
cold.
Unit has little or no ventilation
The unit is being over used.
Check specs on unit instillation if
these are all meet and unit is not
being over used then shut down unit
Call MERQUIP
Stop tap open but unit has slow or no
cold water
Filter needs changing, water supply
is blocked or there is not enough
water pressure
Replace filter, if still slow shut down
unit and Call MERQUIP
Sparkling water has little or no fizz
CO2 bottle empty, CO2 pressure
below 3 Bar or the water temp is too
high
Adjust CO2 pressure check water
outlet temp is below 10deg
C
then
replace CO2 bottle if fault not fixed
shut down unit and Call MERQUIP
Only gas comes out of Sparkling
water outlet
Water supply is not sufficient or there
is none at all
Safety NO WATER system has
tripped
Check to see if red NO WATER light
is on make sure stop tap is open if
fault continues shut down unit Call
MERQUIP
Still water comes out sparkling
Not enough water supply or
clogged valves
Shut down unit
Call MERQUIP
Trouble shooting
FOR SERVICE CALL MERQUIP 0800 636 0 636
Unit shutdown page 30