Operation
20
04.00 | Clamping device SVP-2D | Assembly and Operating Manual | en | 0289025
6.2 Pressure control device
Display: Software version
Display: Operating mode
• Connect the device to the mains voltage (100-240 VAC / 24
VDC / 4,16 A) using the supplied power supply unit.
From software version SV 1.4:
Switch on the clamping device
via the main switch on rear panel.
– The 8-digit LCD display of the pressure control device will
show the software version.
– The display switches into operating mode after
approximately 2 seconds.
• The device is operated via the function keys.
– Activate the target pressure using the key (P).
– The target pressure is entered using the arrow keys (← / ↑).
– Use (←) to move the blinking cursor and (↑) to change the
digit value.
– Use the (OK) key to confirm the entry and display the target
value.
• Pressure values from the memory
– Press the (P) key several times to select from a total of 10
pressure values from the memory.
– Pressing OK will confirmed the selected pressure value.
– The pressure values are displayed from "S0" to "S9" and can
be set individually.