background image

Smart card readers / Lecteurs de cartes à puce

Mullion / Meneau de porte

Technical Specifications

Mullion

Single Gang

Model

KT-MUL-MT-KP

KT-MUL-MT

KT-MUL-SC

KT-SG-MT-KP

KT-SG-MT

KT-SG-SC

RF technologies

13.56 MHz

125 kHz

13.56 MHz

125 kHz

13.56 MHz

13.56 MHz

125 kHz

13.56 MHz

125 kHz

13.56 MHz

Power consumption (mA) @ 12
VDC Peak / AVG

200 mA / 80 mA 120 mA / 70 mA 120 mA / 70 mA 200 mA / 80 mA 120 mA / 70 mA

120 mA / 70 mA

Weight

110 g (0.24 lb) 110 g (0.24 lb) 105 g (0.23 lb)

175 g (0.4 lb)

170 g (0.37 lb)

165 g (0.36 lb)

Capacitive Touch Keypad with
backlighting

Yes

No

No

Yes

No

No

Typical read range

125 kHz

ioProx ID-1 credentials (Cards)

Up to 5.1 cm (2")

--

Up to 6.8 cm (2.7")

--

Typical read range 13.56 MHz
MIFARE Plus EV1, encrypted
sector, ID-1 credentials (Cards)

Up to 3.8 cm (1.5")

Up to 4.3 cm (1.7")

Mounting

Mullion

Single Gang, North America / Europe

Dimension in millimeters
(H x W x D)

115.8 x 44.6 x 24.7

115.8 x 71.5 x 24.7

Dimensions in inches
(H x W x D)

4.56 x 1.75 x 0.97

4.56 x 2.81 x 0.97

Supported credentials 125 kHz

ioProx and HID®

--

ioProx and HID®

--

Supported credentials 13.56 MHz

MIFARE Plus EV1 and ISO/IEC 14443A and 14443B

Wiring terminal

6 screwless poles

Tamper

Optical

Wiegand communication Formats

Kantech SSF / Kantech XSF / 26-bit / 34-bit

Sounder

Integrated

AES-128 security

From the ioSmart card to the reader. From the reader to the access control unit over RS-485.

Output

RS-485: 1 supervised open-drain, up to 750 mA

Operating temperature

- 40°C to +70°C (- 40°F to +158°F). - 35°C to +66°C (- 31°F to +151°F) for UL listed product.

Operating humidity

0 to 95% non-condensing. 85% non-condensing for UL listed product.

LED indicator

Multi-color bar: Red, green, yellow, blue, configurable

Inputs in Wiegand mode

LED and buzzer

Inputs in RS-485

2 to 4, configurable

Input voltage

8.5 VDC to 16 VDC (provided by UL 294 or UL 603 listed, power limited power source).

Housing

Polycarbonate, smoked black

Flammability rating

UL94 V-2

Firmware

Fully upgradable using RS-485

Ingress protection rating

IP55 (not verified by UL).

Communication

RS-485: NIST CAVP validation number AES 3667, key length 128; or Wiegand.

Cabling

3 twisted pairs AWG 22 unshielded or CAT5, up to 150 m (500')

1

Warranty

Limited lifetime

Certifications

FCC/IC, CE, UL294, NIST, FIPS 197, RoHS, WEEE

1

Refer to the installation manual for more details on wiring distances.

Summary of Contents for tyco Kantech T-MUL-MT-KP

Page 1: ...edentials 13 56 MHz MIFARE Plus EV1 and ISO IEC 14443A and 14443B Wiring terminal 6 screwless poles Tamper Optical Wiegand communication Formats Kantech SSF Kantech XSF 26 bit 34 bit Sounder Integrated AES 128 security From the ioSmart card to the reader From the reader to the access control unit over RS 485 Output RS 485 1 supervised open drain up to 750 mA Operating temperature 40 C to 70 C 40 F...

Page 2: ...s EV1 et ISO IEC 14443A et 14443B Bornes de câblage 6 pôles sans vis Anti sabotage Optique Formats de Communication Wiegand Kantech SSF Kantech XSF 26 bits 34 bits Avertisseur sonore Intégré Sécurité cryptage AES 128 À partir de la carte ioSmart jusqu au lecteur À partir du lecteur jusqu au contrôleur d accès en mode RS 485 Sortie RS 485 1 supervisée drain ouvert jusqu à 750 mA Température de fonc...

Page 3: ...ment off and on the user is encouraged to try to correct the interference by one or more of the following measures n Re orient the receiving antenna n Relocate the alarm control with respect to the receiver n Move the alarm control away from the receiver n Connect the alarm control into a different outlet so that alarm control and receiver are on different circuits If necessary the user should con...

Page 4: ...con troller Le schéma suivant démontre comment connecter le lecteur pour les connexions d entrées facultatives Ce câblage s ajoute à la con nexion au contrôleur hôte Alarm Alarme Input 1 Input 2 5 6K 5 6K 5 6K Only use copper conductors Utilisez uniquement des conducteurs en cuivre GND D0 X BUZ I2O PWR D1 X LED I1 Zone termination NC NO NEOL single or double EOL termination Zone de terminaison ter...

Reviews: