Assembly
01.00|KSP3-IM, KSP3-LH-IM |en
25
NOTE
The TANDEM base plates do not have a connection possibility for
the inductive proximity switches on the TANDEM clamping blocks.
The function for monitoring the jaw position can only be
connected externally. When joining, make sure the air feed-
throughs for the clamping system and the base plate are precisely
aligned.
• Screw the two parts together using the four screws (item 84)
from the accessory kit. In doing so, observe tightening torques.
• Remove the locking screws from the pneumatic connections on
the base plate.
• Connect the diaphragm pressure switch and set the switch to
the required minimum pressure.
NOTE
The clamping force block is delivered with all four air connections
sealed. On the base side with set-screws (item 60) and on the front
with locking screws (item 23).
• When using the air purge via connection 5, the two sound
absorbers (V) must be removed and replaced by set-screws
• Requirements for compressed air supply: Compressed air,
compressed air quality according to ISO 8573-1: 7:44.
• Unconditioned compressed air contains moisture as well as
dust and oil particles, all of which can lead to malfunctions or
premature wear in the clamping force block. The oiler should
be no more than 2 meters from the coupling point.
• The clamping force block has two more base connections (
6/7
)
for direct lubrication through the machine table. These
connections come sealed on delivery with set-screws (item 62).