Maintenance and care
44
01.00|KSP3-IM, KSP3-LH-IM |en
• Disassemble the supply cable to the
pin terminal of the inductive proximity
switches on the separable elbow
fitting
• Remove the screw (item 71) and take
the retaining plate (item 12) together
with the cover (item 14) and the
proximity switches (item 36) out of the
body
• Each proximity switch is fastened with
a hexagon nut and washer (item 72)
• The counter-supports (item 13) can be
disassembled simultaneously
• Pull out the plug (item 81)
• Unscrew the screws (item 84) and the
fitting screws (item 82) and
disassemble the clamping system from
the machine table
• If using clamping sleeves (item 85),
remove them from the housing