Maintenance
106
12.00 | SWS | Assembly and Operating Manual | en | 389456
Mount new sensor assembly
Ø
Carefully screw the new sensor (6) or (7) into SWK (4) until the
sensor (6) or (7) touches the detection shaft.
Ø
Unscrew sensor (6) or (7) by half a turn.
Ø
Hold sensor (6) or (7) in this position and connect sensor cable.
✓
The sensor LED will illuminate.
Ø
Apply screw lock to screw (3) and fasten sensor (6) or (7) with
screw (3).
WARNING Risk of damage to the sensor! Carefully tighten
screw (3) until screw (3) engages in the sensor thread, then
tighten another 1/4 turn.
Check new sensor assembly
Ø
Connect all compressed air lines.
Ø
Secure the adapter plate (2) to SWK (4) with screws (5).
✓
Max. tightening torque: 1.13 Nm
Ø
Guide the sensor cable along the cable ducts in the adapter
plate (2) and secure it with screws (1).
✓
Max. tightening torque: 0.9 Nm
Ø
Lock and unlock the locking piston and check the signals of the
sensors.