Maintenance
12.00 | SWS | Assembly and Operating Manual | en | 389456
105
SWS for hollow
wrist robots
SWS 011HM
SWS 011HM: Change integrated piston stroke control
Remove defective sensor assembly
Ø
Place the SWA in the storage rack, secure and uncouple it.
Ø
Disassemble the SWK from the robot and safely set the SWK
aside,
Removing the product from the robot arm
Ø
Lock and unlock the locking piston and check the signals of the
sensors.
Ø
Check sensor cable for damage, replace if necessary.
Ø
Switch off the power supply and ensure that there is no residual
energy in the system.
Ø
Loosen the screws (1).
Ø
Loosen screws (5) and remove adapter plate (2) from SWK (4).
IMPORTANT! Damage to the sensor cable possible! When
removing the adapter plate, make sure that the sensor cable
has sufficient play.
Ø
Remove sensor cable and compressed air lines.
Ø
Loosen screw (3) and remove damaged sensor (6) or (7).