Assembly and settings
26
02.00 | JGP-P | Assembly and Operating Manual | en | 1469637
5.2.2 Pneumatic connection
NOTE
• Observe the requirements for the compressed air
supply,
.
• In case of compressed air loss (cutting off the energy line), the
components lose their dynamic effects and do not remain in a
secure position. However, the use of a SDV-P pressure
maintenance valve is recommended in this case in order to
maintain the dynamic effect for some time. Product variants
are also offered with mechanical gripping force via springs,
which also ensure a minimum clamping force in the event of a
pressure drop.
Air connections
1
Main connections (Hose connection)
(A = open, B = close)
2
Hose-free direct connection at the base
(a = open, b = close)
3
Hose-free direct connection
4
Air purge connection
Hose-free direct connection
6
Product
7
O-ring
8
Attachment
• Open only the air connections that are needed.
• Close unused main air connections using the screw plugs from
the enclosed pack.
• For a hose-free direction connection, use the O-rings from the
enclosed pack.