Assembly and settings
1. Check the evenness of the mounting surface,
.
2. Connect the product via the hose-free direct connection.
3. OR: Connect compressed air lines to the main air
connections "A" and "B".
✓
Remove the locking screws.
✓
Screw in air connections (plug connections).
OR: Screw on throttle valve in order to be able to perform
sufficient throttling and/or damping.
4. Screw the product to the machine/system,
.
✓
If necessary, use appropriate connection elements (adapter
plates).
✓
Observe permissible depth of engagement and if required
strength class.
5. Connect air purge connection if necessary.
6. Attach additional structure to the product if
necessary,
7. Connect the sensor, see assembly and operating manual of the
sensor.
8. Mount the sensor,
21
02.00 | JGP-P | Assembly and Operating Manual | en | 1469637