Assembly and settings
5.4.13.2 Mounting FPS-M8
To be able to mount the sensor, the gripper has to be retrofitted
with a special mounting kit.
1. Move product to the "gripper open" position.
2. Undo the expander bolt (4) and turn the adjustable spindle (5)
to remove the control cam (6) for the inductive monitoring
from the base jaw.
3. Slide control cam (7) out of the mounting kit into the base jaw.
4. Screw the control cam (7) into the base jaw by turning the
adjustable spindle (5) until the setting dimension I3 is
reached
.
5. Fix the control cam (7) with the expander bolt (4). The control
cam must no longer move after assembly.
6.
For sizes 125-1, 200-1 and 200-2:
Slide spacer (8) into the
bracket (2) to the stop.
7. Slide the sensor (1) to the stop into the bracket (2).
8. Tighten the screw (3) on the bracket (2).
Tightening torque: 0.2 Nm
9. Adjust sensor (1), see Translation of Sensor Assembly and
Operating Manual.
45
02.00 | JGP-P | Assembly and Operating Manual | en | 1469637