Assembly and settings
Mounting surface, sizes: A - to 100, B - from 125
1.
IMPORTANT! The size of the additional structure may not
exceed the recess of the cover.
2. Remove the screws (1) from the cover (2).
3. Remove the cover (2).
4.
IMPORTANT! Ensure that no foreign objects can enter the
gripper.
Attach additional structure within the recess (4),
✓
Use centering sleeves (3) between gripper and additional
structure. Centering sleeves can be ordered from SCHUNK.
✓
With sizes 50 – 100 the threaded holes (5) of the cover (2)
are used for securing the additional structure.
✓
From size 125, the additionally attached threaded holes (6)
are used for securing the additional structure.
29
02.00 | JGP-P | Assembly and Operating Manual | en | 1469637