Maintenance
54
02.00 | JGP-P | Assembly and Operating Manual | en | 1469637
7.5.3 Replace seal (variant with gripping force maintenance "I.D.
gripping")
WARNING
Risk of injury due to spring forces!
Products that use spring force or have gripping force
maintenance contain parts that are under spring tension. This can
cause components to move unexpectedly when being
dismantled, which may result in serious injuries.
•
Carefully dismantle the product.
1. Remove all compressed air lines,
2. Remove product from the system/machine.
3. Remove the cover (11).
4. Mark the installation position of the base jaws (3) on the
housing (10).
5.
IMPORTANT! Cover (5) is under spring tension. Remove
carefully.
Carefully unscrew the screws and remove the cover (5) and the
spring (7).
6. Unscrew screw (8) and take cylinder piston (4) out of the
housing (10).
7. Push the wedge hook (1) out of the housing (10).
8. Take base jaws (3) out of the housing (10).
9. Remove old seals (2, 6 and 9).
10. Clean guiding areas.
11. Attach new seals (2 and 9) from the seal kit.
12. Re-lubricating guiding areas
13. Insert base jaws (3) into the housing (10).
IMPORTANT! Observe installation position of the base jaws
(3) in the housing (10).