Maintenance
56
28.00 | DPG-plus | Assembly and Operating Manual | en | 389031
7.6.3 Version with gripping force maintenance I.D.
Position of the item numbers:
•
Previous version:
Assembly drawing (previous version)
•
Successor version:
Assembly drawing (successor version)
WARNING
Risk of injury due to spring forces!
The cover is under spring tension.
•
Carefully disassemble the product.
Disassembling
Ø
Remove the compressed air hose.
Ø
Unfasten and remove the screws (47).
Ø
Previous version:
Remove the cover (5) and seal (37/20).
Successor version:
Remove the cover (5) and flat seal (20).
Ø
Mark the installation positions of the base jaw (2/7) and the
side cover (12) on the housing (1).
Ø
Previous version:
Unscrew screws (42). Remove the side
cover (12) and the gasket (14).
For DPG-plus 240 / 300: Remove O-ring (39).
Successor version:
Unscrew and remove screws (42), remove
the side cover (12) and the flat seal ring (39).
IMPORTANT! Do not disassemble the filler piece (18) for
maintenance purposes, as the product may leak. If the filler
piece (18) is nevertheless disassembled, seal the filler piece
(18) with liquid sealant on reassembly.
Ø
WARNING Risk of injury due to spring forces! The cover is
under spring tension.
Clamp the product between the housing (1) and cover (9) in the
vise so that it is still possible to remove the four screws (46).
Ø
Unfasten and remove the screws (46).
Ø
Carefully open the vise until the compression spring (25) has no
more tension.
Ø
Remove the cover (9) and the compression spring (25).
Ø
Remove the centering sleeves (19).