Assembly
38
28.00 | DPG-plus | Assembly and Operating Manual | en | 389031
Setting the sensor in "Standard mode"
Alternatively for size: 40 - 160, except 50
Ø
Turn the sensor 1 (1) into the groove (2).
OR: Slide the sensor 1 (1) into the groove (2) until the sensor 1
(1) stops at the T-nut (3).
Ø
Secure the sensor 1 (1) using the set-screw (4).
Tightening torque: 10 Ncm
Ø
Adjust sensor 1 (1), see sensor assembly and operating manual.
Ø
Repeat steps for sensor 2.
NOTE
If there is no T-nut available, slide the sensor according to dimension
I1 into the groove (2),
Setting dimensions for magnetic switches
34].
5.4.6 Mounting programmable magnetic switch MMS 22-PI2
CAUTION
Risk of damage to the sensor during assembly!
•
Observe the maximal tightening torque.
NOTE
If there is no T-nut available, slide the sensor according to dimension
I1 into the groove (2),
Setting dimensions for magnetic switches
34].
Ø
Turn the sensor (1) into the groove (2).
OR: Slide the sensor (1) into the groove (2) until the sensor (1)
stops at the T-nut (3).
Ø
Secure the sensor (1) using the set-screw (4).
Tightening torque: 10 Ncm
Ø
Adjust sensor (1), see sensor assembly and operating manual.