![Schulze BS-350 LST Original Operating Manual Download Page 60](http://html1.mh-extra.com/html/schulze/bs-350-lst/bs-350-lst_original-operating-manual_1214966060.webp)
9
Maintenance and cleaning
9.1
Maintenance
60
/80
Table saw BS-350 LST, BS-400 LST-E230, BS-400 LST-E400, BS-500 LST
Table 5:
Maintenance plan
Interval
Maintenance work
Remarks
−
Check bearing for wear. The service life is 500 to
1000 h
Bearings may only be re-
placed by the manufacturer.
Please ask customer service.
3 months
−
Check the entire drive and the electrical parts of the
machine for correct setting and function.
The test should be carried out
by the manufacturer or by an
authorized representative.
annually, before
first use
−
Have the machine checked for electrical safety in
accordance with VBG4 [Accident-prevention regula-
tions], §5.
By qualified electricians. The
test must be documented.
See manufactur-
er’s instructions
−
Maintenance work on the water pump
For information, please refer
to the manufacturer’s instruc-
tions
Measures after Maintenance is Carried Out
After completing the maintenance and before turning on the machine, per-
form the following steps:
1.
Check all previously loosened screw connections for tightness.
2.
Check that all previously removed guards and covers are properly
reinstalled.
3.
Make sure that all electrical safety devices (e.g. emergency stop
buttons) are working properly.