![Schulze BS-350 LST Original Operating Manual Download Page 22](http://html1.mh-extra.com/html/schulze/bs-350-lst/bs-350-lst_original-operating-manual_1214966022.webp)
3
Safety
3.10 Protective devices
22
/80
Table saw BS-350 LST, BS-400 LST-E230, BS-400 LST-E400, BS-500 LST
Main switch with emergency off function
Integrated in the control box are a main switch with emergency off function
(1) a thermal overcurrent relay and an undervoltage release.
Green button - 1 = switch machine on
Red button - 0 = switch machine off
.
Position of the control box on the Table saw BS-350 LST, BS-
400 LST-E230, BS-400 LST-E400, BS-500 LST
A bimetallic overload protector protects the drive and prevent the restarting
of the motor outside the permissible temperature range. An overload can oc-
cur, e.g. by overly fast cut, hard material, dull cutting blade or route of the
cut.
The built-in under-voltage release prevents, e.g. after a power failure, the
accidental restart of the drive when voltage is applied again.
1
1