86
When service is over, the compressor oil, oil filter element and oil separator element must be disposed according
to the local regulations.
See further directions in “Environmental Orientations and Recommendations”.
TABLE 14.1
For your SCHULZ rotary screw air compressor to have a guaranteed useful life and operate properly, it needs periodical maintenance as
mentioned in the chapter Preventive Maintenance. Table 14.1 indicates the code of the components and of the lubricant oil, which are pur-
chased at a SCHULZ AUTHORIZED DEALER.
14. MAINTENANCE PARTS
15. REMOVING MAINTENANCE PARTS - DISPOSAL
16. CORRECTIVE MAINTENANCE
To guarantee the SAFETY and RELIABILITY of the product, the repairs, maintenance and adjustments must
be performed through the nearest SCHULZ AUTHORIZED DEALER, which always uses genuine parts.
ATTENTION
Description
SRP 3005
SRP 3008
SRP 3010 II
SRP 3010
SRP 3015 II
SRP 3015
SRP 3020
SRP 3025
SRP 3030
SRP 3040
SH-46 SYNTHETIC (Kluber).
lubricant oil (20-l drum)
101.0239-0/AT 101.0239-0/AT
101.0239-0/AT
101.0239-0/AT 101.0239-0/AT 101.0239-0/AT 101.0239-0/AT 101.0239-0/AT
LUB SCHULZ SYNTHETIC
lubricant oil (20-l drum)
101.0173-0
101.0173-0
101.0173-0
101.0173-0
101.0173-0
101.0173-0
101.0173-0
101.0173-0
LUB SCHULZ MINERAL
lubricant oil (20-l drum)
830.1257-0
007.0184-0/AT
Metalic carcass
60318005/AT
007.0184-0/AT 007.0184-0/AT 007.0184-0/AT 007.0184-0/AT 007.0136-0/AT
Air filter
Plastic carscass
007.0512-0/AT
Oil filter
007.0177-0/AT 007.0177-0/AT
007.0177-0/AT
007.0177-0/AT 007.0023-1/AT 007.0023-1/AT 007.0023-1/AT 007.0023-0/AT
Air/ oil separator element
007.0233-0/AT 007.0233-0/AT
007.0233-0/AT
007.0233-0/AT 007.0413-0/AT 007.0413-0/AT 007.0413-0/AT 007.0413-0/AT
Tensiometer with 1 rod
021.0097-0/AT 021.0097-0/AT
021.0097-0/AT
021.0097-0/AT 021.0097-0/AT 021.0097-0/AT 021.0097-0/AT 021.0097-0/AT