background image

1

AZM300

Operating instructions

Solenoid interlock

EN

1.  About this document

1.1  Function

This operating instructions manual provides all the information you 

need for the mounting, set-up and commissioning to ensure the safe 

operation and disassembly of the safety switchgear. The operating 

instructions must be available in a legible condition and a complete 

version in the vicinity of the device.

1.2  Target group: authorised qualified personnel

All operations described in this operating instructions manual must 

be carried out by trained specialist personnel, authorised by the plant 

operator only.

Please make sure that you have read and understood these operating 

instructions and that you know all applicable legislations regarding 

occupational safety and accident prevention prior to installation and 

putting the component into operation.

The machine builder must carefully select the harmonised standards 

to be complied with as well as other technical specifications for the 

selection, mounting and integration of the components.

1.3  Explanation of the symbols used

Information, hint, note:

This symbol is used for identifying useful additional information.

Caution:

 Failure to comply with this warning notice could 

lead to failures or malfunctions.

Warning:

 Failure to comply with this warning notice could 

lead to physical injury and/or damage to the machine.

1.4  Appropriate use

The products described in these operating instructions are developed  

to execute safety-related functions as part of an entire plant or machine. 

It is the responsibility of the manufacturer of a machine or plant to 

ensure the correct functionality of the entire machine or plant.

The safety switchgear must be exclusively used in accordance with 

the versions listed below or for the applications authorised by the 

manufacturer. Detailed information regarding the range of applications 

can be found in the chapter "Product description".

1.5  General safety instructions

The user must observe the safety instructions in this operating 

instructions manual, the country specific installation standards as well 

as all prevailing safety regulations and accident prevention rules.

Content

1  About this document

1.1  Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.2 

Target group: authorised qualified personnel

. . . . . . . . . . . . . . . . . .1

1.3  Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.4  Appropriate use  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.5  General safety instructions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.6  Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

1.7  Exclusion of liability  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2  Product description

2.1  Ordering code  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.2  Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.3  Comprehensive quality insurance to 2006/42/EC  . . . . . . . . . . . . . .2

2.4  Purpose  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.5  Technical data  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

2.6 

Safety classification

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

3  Mounting

3.1  General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

3.2  Manual release  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

3.3  Emergency exit -T/-T8 or emergency release -N. . . . . . . . . . . . . . .5

3.4  Mounting with mounting plate  . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

3.5  Dimensions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

3.6  Actuator and accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

4  Electrical connection

4.1  General information for electrical connection. . . . . . . . . . . . . . . . . .7

5  Operating principle, actuator coding and latching force adjustment

5.1  Magnet control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

5.2  Mode of operation of the safety outputs. . . . . . . . . . . . . . . . . . . . . .7

5.3  Actuator coding  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

5.4  Adjustment of the latching force. . . . . . . . . . . . . . . . . . . . . . . . . . . .7

6  Diagnostic function

6.1  Diagnostic-LEDs  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

6.2  Solenoid interlock with conventional diagnostic output  . . . . . . . . . .7

6.3  Solenoid interlock with serial diagnostic function SD. . . . . . . . . . . .9

7  Set-up and maintenance

7.1  Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

7.2  Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

8  Disassembly and disposal

8.1  Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

8.2  Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

9  Appendix

9.1  Wiring examples  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

9.2 

Wiring configuration and connector accessories

. . . . . . . . . . . . . . 11

10  EU Declaration of conformity

x.000 / 04.2020 / v

.A.   -   103001

171-EN / O / 2020-04-20 / 

AE-Nr

. 12264

EN

Operating instructions. . . . . . . . . . . .pages 1 to 12

Original

Summary of Contents for AZM300

Page 1: ...be exclusively used in accordance with the versions listed below or for the applications authorised by the manufacturer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this operating instructions manual the country specific installation standards as well as all ...

Page 2: ... The safety switchgears are classified according to ISO 14119 as type 4 interlocking devices Designs with individual coding are classified as highly coded The different variants can be used as safety switch with interlocking function either as solenoid interlock If the risk analysis indicates the use of a monitored interlock then a variant with the monitored interlock is to be used labelled with t...

Page 3: ...e 24 VDC 0 25 A Rated operating current Ie 0 25 A Leakage current Ir 0 5 mA Voltage drop Ud 4 V Cross wire monitoring by device Yes Test pulse duration 0 3 ms Test pulse interval 1 000 ms Classification ZVEI CB24I Source C2 Sink C1 C2 Electrical data Diagnostic output Diagnostic output OUT Switching element p type short circuit proof Utilisation category DC 12 Ue Ie 24 VDC 0 05 A DC 13 Ue Ie 24 VD...

Page 4: ...ng this is detected by the solenoid interlock and the safety gates Y1 Y2 switch off When such a fault occurs the protection equipment may open immediately just once before the safe condition of the machine is reached The system reaction of category 2 allows that a fault can occur between tests causing the loss of the safety function which is detected by the test 3 Mounting 3 1 General mounting ins...

Page 5: ...ver is loosely supplied The lever should be fastened to the position intended with the supplied screws before first being used The lever should be installed on the unlocking triangle in such a way that the arrow on the triangle and the lever pivot are congruent The installation of the lever is possible on both sides The opposite is to be sealed with the seal included with delivery Emergency exit T...

Page 6: ... 5 34 5 63 13 5 8 5 35 Ø26 Emergency exit T8 3 6 Actuator and accessories Actuator AZ AZM300 B1 not included in delivery 55 16 4 127 Ø6 7 35 18 5 37 4 8 6 46 23 4 Ø5 Mounting plate MP AZ AZM300 1 available as accessory 40 24 R2 5 101 R 1 5 R 8 18 5 78 Ø6 8 8 1x45 Lockout tag SZ 200 1 available as accessory t 3mm 107 37 23 5 13 5 Ø10 29 12 5 85 Ø4 25 3 5 10 Bowden cable release ACC AZM300 BOW M M O...

Page 7: ...n of the safety outputs Safety outputs are disabled if the error warning is active for 30 minutes The signal combination diagnostic output disabled and safety channels still enabled can be used to stop the production process in a controlled manner After the rectification of the error the error message is reset by opening the corresponding safety guard For devices with serial diagnostic a bit can b...

Page 8: ...Safety outputs Y1 Y2 Diagnostic output OUT Power to unlock Power to lock green red yellow AZM300Z AZM300B Guard open 24 V 0 V 0 V 24 V On Off Off 0 V 0 V 0 V Door closed not locked 24 V 0 V On Off Flashes 0 V 24 V 24 V Door closed locking impossible 0 V 24 V On Off Flashes 0 V 24 V 0 V Door closed and locked 0 V 24 V On Off On 24 V 24 V 24 V Error warning 1 0 V 24 V On Flashes 2 Off 24 V1 24 V1 0 ...

Page 9: ...es For the evaluation of the serial diagnostics line either the PROFIBUS Gateway SD I DP V0 2 or the Universal Gateway SD I U are used This serial diagnostic interface is integrated as a slave in an existing field bus system In this way the diagnostic signals can be evaluated by means of a PLC The necessary software for the integration of the SD Gateway is available for download at products schmer...

Page 10: ...nditions must be previously checked and met 1 Check max axial misalignment of actuator and solenoid interlock 2 Check max angular misalignment see Mounting part 3 Fitting and integrity of the cable connections 4 Check the switch enclosure for damage 5 Remove particles of dust and soiling 6 For variants with an emergency exit and emergency release the following is to be considered For variants with...

Page 11: ...in configuration of the connector 5 8 4 3 2 1 7 6 Colour codes of the Schmersal connectors Poss colour codes of other customary connectors With conventional diagnostic output With serial diagnostic function IP67 IP69 to DIN 47100 IP69K PVC to IEC 60947 5 2 2007 A1 Ue 1 WH BN BN X1 Safety input 1 2 BN WH WH A2 GND 3 GN BU BU Y1 Safety output 1 4 YE BK BK OUT Diagnostic output SD output 5 GY GY GY X...

Page 12: ...A1 2013 Notified body for the prototype test TÜV Rheinland Industrie Service GmbH Alboinstr 56 12103 Berlin ID n 0035 EC prototype test certificate 01 205 5281 02 15 Person authorised for the compilation of the technical documentation Oliver Wacker Möddinghofe 30 42279 Wuppertal K A Schmersal GmbH Co KG Möddinghofe 30 42279 Wuppertal Germany Phone 49 202 6474 0 Telefax 49 202 6474 100 E Mail info ...

Reviews: