AZM300

Operating instructions

Solenoid interlock

EN

Minimum distance between two solenoid interlocks

as well as other systems with same frequency (125 kHz)

250

250

A

A

B

B

The minimum distance from metallic securing surfaces to the face side 

"A" and underside "B" of the device is 5 mm.

250

70

3.2  Manual release

For the machine set-up, the solenoid interlock can be unlocked in a de-

energised condition. The solenoid interlock is unlocked by turning the 

manual release in the position 

Q

.

The normal locking function is only restored after the manual release 

has been returned to its original position 

P

.

Caution: do not turn beyond the end stop!

After being put into operation, the manual release must be sealed by 

means of the seal, which is included in delivery.

Power

Status

Fault

C

A

B

Key

A: Connector plug M12, 8-pole

B: LED indications

C: Manual release

3.3  Emergency exit -T/-T8 or emergency release -N

With variants that have both emergency exit and emergency release, the 

red lever is loosely supplied. The lever should be fastened to the position 

intended with the supplied screws before first being used.

The lever should be installed on the unlocking triangle in such a way that 

the arrow on the triangle and the lever pivot are congruent.

The installation of the lever is possible on both sides. The opposite is to 

be sealed with the seal included with delivery.

Emergency exit (-T/-T8)

Fitting and actuation only from within the hazardous area.

Emergency release (-N)

Mounting and actuation only outside of the safety guard.

The emergency release should only be used in an emergency. 

The solenoid interlock should be installed and/or protected so 

that an inadvertent opening of the interlock by an emergency 

release can be prevented.

The emergency release must be clearly labelled that it should 

only be used in an emergency. The label can be used that was 

included in the delivery.

To ensure correct operation of emergency exit -T/-T8 and 

emergency release -N, the safety door/guard must not be  

in a mechanically tensioned state.

3.4  Mounting with mounting plate

For doors, which close flush with the door frame, the optional mounting 

late MP-AZ/AZM300-1 can be used.

 

Summary of Contents for AZM300

Page 1: ...be exclusively used in accordance with the versions listed below or for the applications authorised by the manufacturer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this operating instructions manual the country specific installation standards as well as all ...

Page 2: ... The safety switchgears are classified according to ISO 14119 as type 4 interlocking devices Designs with individual coding are classified as highly coded The different variants can be used as safety switch with interlocking function either as solenoid interlock If the risk analysis indicates the use of a monitored interlock then a variant with the monitored interlock is to be used labelled with t...

Page 3: ...e 24 VDC 0 25 A Rated operating current Ie 0 25 A Leakage current Ir 0 5 mA Voltage drop Ud 4 V Cross wire monitoring by device Yes Test pulse duration 0 3 ms Test pulse interval 1 000 ms Classification ZVEI CB24I Source C2 Sink C1 C2 Electrical data Diagnostic output Diagnostic output OUT Switching element p type short circuit proof Utilisation category DC 12 Ue Ie 24 VDC 0 05 A DC 13 Ue Ie 24 VD...

Page 4: ...ng this is detected by the solenoid interlock and the safety gates Y1 Y2 switch off When such a fault occurs the protection equipment may open immediately just once before the safe condition of the machine is reached The system reaction of category 2 allows that a fault can occur between tests causing the loss of the safety function which is detected by the test 3 Mounting 3 1 General mounting ins...

Page 5: ...ver is loosely supplied The lever should be fastened to the position intended with the supplied screws before first being used The lever should be installed on the unlocking triangle in such a way that the arrow on the triangle and the lever pivot are congruent The installation of the lever is possible on both sides The opposite is to be sealed with the seal included with delivery Emergency exit T...

Page 6: ... 5 34 5 63 13 5 8 5 35 Ø26 Emergency exit T8 3 6 Actuator and accessories Actuator AZ AZM300 B1 not included in delivery 55 16 4 127 Ø6 7 35 18 5 37 4 8 6 46 23 4 Ø5 Mounting plate MP AZ AZM300 1 available as accessory 40 24 R2 5 101 R 1 5 R 8 18 5 78 Ø6 8 8 1x45 Lockout tag SZ 200 1 available as accessory t 3mm 107 37 23 5 13 5 Ø10 29 12 5 85 Ø4 25 3 5 10 Bowden cable release ACC AZM300 BOW M M O...

Page 7: ...n of the safety outputs Safety outputs are disabled if the error warning is active for 30 minutes The signal combination diagnostic output disabled and safety channels still enabled can be used to stop the production process in a controlled manner After the rectification of the error the error message is reset by opening the corresponding safety guard For devices with serial diagnostic a bit can b...

Page 8: ...Safety outputs Y1 Y2 Diagnostic output OUT Power to unlock Power to lock green red yellow AZM300Z AZM300B Guard open 24 V 0 V 0 V 24 V On Off Off 0 V 0 V 0 V Door closed not locked 24 V 0 V On Off Flashes 0 V 24 V 24 V Door closed locking impossible 0 V 24 V On Off Flashes 0 V 24 V 0 V Door closed and locked 0 V 24 V On Off On 24 V 24 V 24 V Error warning 1 0 V 24 V On Flashes 2 Off 24 V1 24 V1 0 ...

Page 9: ...es For the evaluation of the serial diagnostics line either the PROFIBUS Gateway SD I DP V0 2 or the Universal Gateway SD I U are used This serial diagnostic interface is integrated as a slave in an existing field bus system In this way the diagnostic signals can be evaluated by means of a PLC The necessary software for the integration of the SD Gateway is available for download at products schmer...

Page 10: ...nditions must be previously checked and met 1 Check max axial misalignment of actuator and solenoid interlock 2 Check max angular misalignment see Mounting part 3 Fitting and integrity of the cable connections 4 Check the switch enclosure for damage 5 Remove particles of dust and soiling 6 For variants with an emergency exit and emergency release the following is to be considered For variants with...

Page 11: ...in configuration of the connector 5 8 4 3 2 1 7 6 Colour codes of the Schmersal connectors Poss colour codes of other customary connectors With conventional diagnostic output With serial diagnostic function IP67 IP69 to DIN 47100 IP69K PVC to IEC 60947 5 2 2007 A1 Ue 1 WH BN BN X1 Safety input 1 2 BN WH WH A2 GND 3 GN BU BU Y1 Safety output 1 4 YE BK BK OUT Diagnostic output SD output 5 GY GY GY X...

Page 12: ...A1 2013 Notified body for the prototype test TÜV Rheinland Industrie Service GmbH Alboinstr 56 12103 Berlin ID n 0035 EC prototype test certificate 01 205 5281 02 15 Person authorised for the compilation of the technical documentation Oliver Wacker Möddinghofe 30 42279 Wuppertal K A Schmersal GmbH Co KG Möddinghofe 30 42279 Wuppertal Germany Phone 49 202 6474 0 Telefax 49 202 6474 100 E Mail info ...

Reviews: