Dimension size S

Specification

The „ME“-data sheet contains additional information for InMax actuators

of the size „S“, for the optimization and simplification in regard to

planning, installation and initial start up. It provides influences of

external factors in reference to the safe initiation of the actuators.

In particular it represents the installation, as well as different dampers,

fire protection dampers and armatures. Additionally describing different

accessory  elements  and  their  mounting  to  the  actuator.

Specification

E X P L O S I O N P R O O F

Schischek GmbH 

Germany, Mühlsteig 45, Gewerbegebiet Süd 5, 90579 Langenzenn, Tel. +49 (0)9101 9081-0, Fax +49 (0)9101 9081-77, E-Mail [email protected]

InMax-.. extra information ME – size S

S

T

10-position switch (S)
Push button (T)

3-colour LED

u

Dimension, drill template

u

Control elements: switch – push button – LED

u

Outdoor installation

u

Mounting using form-fitting shaft connection (square shaft)

u

Mounting using clamp mounting (round shaft)

u

Mounting on butterfly valves and ball valves

u

Mounting InSwitch

Dimensions – drill template

Control elements: switch – push button – LED

Outdoor installation

Switch – push button – LED for programming,

behind dummy plug

InMax – extra information ME

118,5

30

30

14

210

74

95

80

Dimension in mm

Side R

Side L

6 × Ø 4,4

6 × M 4

Double sqaured 12 × 12 mm

60

incl. radius

of bend for

the cable

All InMax actuators are equipped with a 10 position switch a push button and a multicolor
LED for calibration. These control elements are to be found cable-laterally behind the two
middle sectioned dummy plugs. For operation these must be removed. The calibration can
be achieved despide lining up tension at the actuator. It has to be of great concern that
the dummy plugs must be rescrewed in order to comply with the IP-protection class. The
operation of the switch and button has to be done by means of a small screwdriver. Force
with strong pressure and /or rotation is to be avoided in any case, since otherwise control
 electronics can be damaged irreparably. By bad visibilities a flashlight should be used.
Attitudes of torque and running time can be achieved also before mounting. The adjustment
of angle of rotation can be started only with an outside load and accurate mounting.

RST

When mounting actuator outdoors it has to be certain that the actuator is protected against
direct sun exposure (heat and UV), rain and snow by employing an enclosure roof. Supply
voltage is to be applied immediately after mounting in order to assure integrated heating
at start. Since explosion proof actuators  must have internal safety temperature limiters,
these may not be exposed neither at storage nor during operation to a too high temperature.
Otherwise  the  limiters  could  respond  and  switch  of  the  actuator  irreversibly.

For additional electrical data have a look at extra information „EL“

Summary of Contents for InMax Revolution

Page 1: ...0 sec at 90 1 sec at 90 On off 2 contacts 5 85 fire trigger SB 7 5 7 6 InMax 15 F1 15 Nm 24 240 VAC DC 3 15 30 60 120 sec at 90 1 sec at 90 On off SB 1 4 1 5 InMax 15 SF1 15 Nm 24 240 VAC DC 3 15 30 60 120 sec at 90 1 sec at 90 On off 2 contacts 5 85 SB 1 4 1 5 InMax 15 BF1 15 Nm 24 240 VAC DC 3 15 30 60 120 sec at 90 1 sec at 90 On off 2 contacts 5 85 fire trigger SB 7 5 7 6 InMax VAS Type as abo...

Page 2: ...operation of actuators with spring return danger of injury exists with release let go the allen key Integral heater integral heater controlled for ambient temperature down to 40 C Housing material aluminium die cast housing painted optional in stainless steel version AISI 316 Type InMax VAS amercoat painting type InMax CTS Dimensions L W H 210 95 80 mm for diagramm see extra information ME S Weigh...

Page 3: ...0 VAC DC a Attention If you use this type of wiring the heater does not work in case of open contact S T Switch Push button Lamp for adjustment behind the blancking plug 10 position switch S Push button T 3 colour LED PA PA PA PA Example InMax 15 BF1 Requested parameter Torque 15 Nm Running time motor 30 sec 90 Result switch position S 02 See extra information EL S A Self adjustment of Angle of ro...

Page 4: ...t to the factory InMax actuators are equipped with an additional temperature sensor to stop the actuator before reaching this max temperature In this case the failure must be eliminated immediately on site H InPro TT The actuator works only with the temperature sensor type InPro TT Details see extra information ME Details see extra information ME InSwitch is an accessory to InMax actuators size S ...

Page 5: ...ltage Uv V Formula for max cable length L at cable cross section A L A l Uv 18V 0 0714 Formula of needed cable cross section A at a cable length of L A 0 0714 l L Uv 18V The EL S data sheet contains additional information for ExMax RedMax and InMax actuators of the size S for the optimization and simplification in regard to planning installation and initial startup It provides influences of extern...

Page 6: ...wn operations l Attache power supply and turn on l Because of inadmissable operation the actuator drove out of safety relevant reasons into an irreversible condition and must be exchanged Accompanying new installation the ambient temperature has to be reduced accordingly Actuator does not work LED does not lights 01 Acuator does not work LED is red blinking 04 l The actuator has been mounted by te...

Page 7: ...d 12 12 mm 60 incl radius of bend for the cable All InMax actuators are equipped with a 10 position switch a push button and a multicolor LED for calibration These control elements are to be found cable laterally behind the two middle sectioned dummy plugs For operation these must be removed The calibration can be achieved despide lining up tension at the actuator It has to be of great concern tha...

Page 8: ...postion must be selected by turning the actuator 180 Mounting 1 Affix tap hole M4 in accordance with drill template on the damper or to a mounting bracket 2 Adjust drive shaft of the actuator with the socket wrench that the drive stands perpendicular to the damper before pluging actuator on to the damper shaft 3 Plug actuator onto damper shaft and fix diagonally with 2 screws 4 Remove the socket w...

Page 9: ...res which require a special adaption Specification E X P L O S I O N P R O O F Schischek GmbH Germany Mühlsteig 45 Gewerbegebiet Süd 5 90579 Langenzenn Tel 49 0 9101 9081 0 Fax 49 0 9101 9081 77 E Mail info de schischek com InMax extra information ME size S 4 4 Mounting to a butterfly valve Mounting to a ball valve 4 Mounting instructions for InMax actuators size S on butterfly valve and ball valv...

Page 10: ...9 0 9101 9081 77 E Mail info de schischek com InMax extra information ME size S Mounting of terminal boxes type InBox via mounting bracket type MKK S to the actuator accessory 2 2 B A 1 Screw mounting bracket MKK S to the actuator A then screw terminal box to the mounting bracket B Mounting bracket MKK S can be mounted every 90 Terminal box mounted above the actuator Terminal box mounted beside th...

Reviews: