5
– FUNCTIONING AND USE
COD.
60M12/24.D.2018
EN
THE PRESENT MANUAL BELONGS TO -
Schenker Italia
- ALL RIGHTS RESERVED
37
5.3.2
Start-up
1. Open the depressurization valve (lever
horizontal)
2. Push for 20-30 sec the red button on the active
carbon filter housing cup in order to purger
the air from the system.
3. Activate the start-up procedure through the
function of the MENU (select the specific
function in the menu mode, exit from menu
mode pushing STOP, and start the procedure
pushing START).
4. Close the depressurization valve when the
display shows the specific message and wait
for the completion of the procedure.
The procedure lasts about 3 minutes, and it can be stopped at any time pushing STOP. After completed the
procedure the system is ready to start normally.