5
– FUNCTIONING AND USE
COD.
60M12/24.D.2018
EN
THE PRESENT MANUAL BELONGS TO -
Schenker Italia
- ALL RIGHTS RESERVED
33
MENU OPTIONS
•
PUMPS
There are 4 options available:
-
P1
the system works with pump1 only. In this case the production will be about 30 lit/h and the
electric consumption will be about 100 watt.
-
P2
the system works with pump2 only. In this case the production will be about 30 lit/h and the
electric consumption will be about 100 watt
-
P1&P2
the system works with one pump only, alternating P1 and P2 every 20 minutes in order to
balance the wearing of the two pumps. Even in this case the production will be about 30 lit/h and
the electric consumption will be about 100 watt.
-
P1+P2
the system works with both pumps. In this case the production will be about 60 lit/h and the
electric consumption will be about 240 watt.
•
WORKING TIME (timer)
It allows to select the working time of the watermaker (1-6 hours). The timer is activated if the START button
is pushed for more than 3 seconds only.
•
BY-PASS
It allows to exclude the sensor (signal pressure switch) that detects the correct cycling of the ERS. The
operation with the by-pass is necessary only in case of malfunctioning of the signal pressure switch (in
example if the system gets blocks, with the message “
SYSTEM BLOCKED
”, not as consequence of a
real hydraulic problem, but just as consequence of the malfunctioning of the probe).