background image

 

15 

 
 
 

3.

 

Operation 

3.1. Remote panel commands 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

KEYBOARD FEATURES 

The panel  keyboard has a total of four push button. The display light switches off after 15 minutes of 
not use. Pushing any  button,  the display will light again, without activate  any other command.  The 
functions of the push buttons are: 
 

START

 Used to start the system. 

If it is pushed shortly the system starts and the unit will run indefinitely until will be pushed STOP. 
If it is pushed for at least 3 seconds the system starts, and will stop automatically after the working 
hours selected with the timer (see menu functions). 
It can anyway be stopped before, pushing STOP. 
It is used as well to scroll the different options in the single menu. 
 

STOP

 Used to stop the system. 

The system, once pushed STOP,  usually doesn’t stop suddenly. It  awaits for the correct positioning  
of the internal valve (2-3 seconds), and then stops automatically.   
If the automatic washing is activated (washing light on), the system, once pushed STOP, will perform 
the automatic washing (1 min) before stops. 
The push button STOP is used as well to exit from the menu function. 
 

WASHING 

Used to rinse the system automatically with fresh water. 

If it is pushed shortly the system will get ready to perform an automatic washing (1 minute long) once 
the system will be stopped.  
If it is pushed for at least 3 seconds the system will just perform a 10 minutes rinsing, without suck 
up sea water. 
 

MENU  

Used to enter into the MENU mode and modify some parameters. 

Pushing it repeatedly the different MENU options can be scrolled. 
On his turn the START push button allows to scroll the different options of the single menu. 
The system recognizes the current value without any further command. 
The STOP push button allows to exit from the MENU function. 

Summary of Contents for 100M220

Page 1: ...aterial required 2 2 Components mounting 2 3 Water intake 2 4 Hydraulic connections 2 5 Electric connections 3 Operating procedures 3 1 Remote panel commands 3 2 First start up procedure 3 3 Normal op...

Page 2: ...alternative to the high pressure pumps of traditional plants utilizes the EN ERGY RECOVERY SYSTEM patented device which amplifies the pressure of common low pres sure pumps and recoup all the hydraul...

Page 3: ...15 cm Height 23 cm Dry weight 11 Kg Connections Seawater intake holder for hose int diam 20 mm Salt water outlet holder for hose int diam 20 mm Filters 5 micron 9 propylene Power supply Pump 230 VAC...

Page 4: ...n introduce inside the allen key also without remove the electric connector Turning clockwise the allen key increases the pressure shut down set whereas turning anti clockwise decrease the pressure sw...

Page 5: ...a beat issued periodi cally by the watermaker unit The unit is constituted of 2 cylinders and a central body containing the hydraulic valve necessary for the system functioning Manometer It is locate...

Page 6: ...lever The valve must be closed during normal functioning lever perpendicular to the valve Such valve has the function to allow the reset in case of a system block It must be opened be fore acting on t...

Page 7: ...p outlet and the watermaker inlet It is fitted with a 5 microns cartridge and protects the watermaker unit from sediments and de bris CA filter white It removes the chlorine from the washing fresh wat...

Page 8: ...necessary to create a suitable wooden or fiberglass structure for the unit if an existing one not available The base of the pump is equipped with vibration damping devices but avoid installing it on...

Page 9: ...d over Allow a minimum on off ball valve on the water intake The hose connections especially if under the seawater level must be secured with double hose clamps It is not advisable to Tee into the eng...

Page 10: ...ection that is continuously under consistent pressure is the pump outlet 5 m filter watermaker inlet connections For this section is necessary to use a good quality PN 15 min rein forced hose An inade...

Page 11: ...backflow valve pump inlet pump outlet 5 microns filter watermaker inlet PN 15 reinforced hose Section 20 mm int diam Low pressure max 3 bar connection watermaker s exhaust dis charge PN 5 stainless st...

Page 12: ...pressure amplifier inside the watermaker unit marked OUT Fresh water connection The connection has to be made using the small hose furnished with the equipment and relevant endowed fittings The conne...

Page 13: ...fer ential switch requested by the local law The section of the cables will be 4 mm2 min The computer box will be powered 12 24V directly from the service batteries or through a 230 12 24 charger Conn...

Page 14: ...14 Wiring connection diagram Watermaker pressure switch Elecrovalve Batteries or charger...

Page 15: ...uddenly It awaits for the correct positioning of the internal valve 2 3 seconds and then stops automatically If the automatic washing is activated washing light on the system once pushed STOP will per...

Page 16: ...or a general service The procedure allows to purge completely the air from the system and from the seawater and the washing fresh water hoses The depres surization valve must be opened before start th...

Page 17: ...e system It can be used as well after a filter replacement or after other maintenance operations Preliminary checks Verify that all components are connected correctly Verify that the filters cartridge...

Page 18: ...Exit from the menu pushing STOP Push WASHING for 3 seconds The display will indicate the remaining day before the first rinsing The function is anyway disabled pushing STOP or after a normal producti...

Page 19: ...mix carefully following the indications on the pack Wear a protection mask in order to avoid in haling product dusts The water temperature doesn t have to be lower than 25 C preferably 3 Close the gre...

Page 20: ...acement Every 6 months Close the grey valve before open the filter Purge periodically the air from the sys tem opening at 45 for a couple of min utes the depressuri zation valve Every 15 days Check th...

Page 21: ...allation water inlet net filter Low production normal or low pressure Exhausted batteries Air in the plant Seal system leak Check battery charge Perform bleeding Contact a Schenker service point Low p...

Page 22: ...nt accessories are guarantee 12 months starting from the date on the de livery document of the merchandise The guarantee does not include expendable materials car tridges active carbon filters membran...

Reviews: