background image

 

22 

 
5.

 

SAFETY WARNINGS. 

 

 

Don’t open the pump box if the power is on. 

 

 

Do not touch the pump  (which can reach high temperatures) when the plant is functioning. 

 

 

Do not locate the pump  near objects either inflammable or that can deteriorate if exposed to 
high temperature. 

 

 

Check if the watermaker is correctly installed eventually  contacting a Schenker service point. 

 

 

Verify that the hoses used for installation are in keeping with the indicated specifications.    

 

 

The water produced using clean sea water will have an average quality of 500-600 ppm TDS. 
Unless the correct cleaning procedures are carried out in accordance with this manual, there 
may be bacteria present in the produced water. Therefore avoid drinking the water produced 
by the plant if an UV sterilizer has not been installed. 

 

 

Avoid using the plant where water is polluted (ports, or close to built-up areas, etc.) 

 
 

 

Children and inexperienced people shall not touch or operate the plant. 

 

 

Check periodically that no leakage is present. Do not switch on the plant when the boat is un-
attended. Avoid installing the plant where an eventual leakage may cause damages and jeop-
ardize the safety of the boat. 

 

 

Unqualified and non-Schenker personnel shall not perform any maintenance work. 

 
6.

 

WARRANTY 

 
The equipment and the relevant accessories are guarantee 12 months starting from the date on the de-
livery  document  of  the  merchandise.  The  guarantee  does  not  include  expendable  materials  (car-
tridges, active-carbon filters, membranes, etc.). The “ERS” pressure amplification device is guaran-
teed 36 months, provided that the annual maintenance is performed in one of Schenker service point. 
The guarantee covers every fault or defect of materials and parts and it is limited to the replacement 
or repair of faulty parts. The expenses for the device disassembly and reinstallation on the boat and 
for the transport of the equipment from or to our Service Point or our  factory will be on customer ac-
count.  
The under guarantee delivered parts transport  will be at customer’s own risk. 
In  case  of  repairs  under  guarantee,  directly  performed  by  our  technicians  on  the  customer  boat,  the 
faulty parts replacement cost will be on Schenker account, while manpower and travel expenses will 
be charged  to the customer. The guarantee does not include the faults caused by negligence in operat-
ing, maintenance and installation of the device (if they are not performed by an authorised Schenker 
Service point). 
If  non-authorized  personnel  perform  the  disassembly,  every  obligation  of  this  guarantee  will  auto-
matically lapse. Schenker Italia can not be held liable for any direct or indirect damage caused by the 
malfunctioning  of  the  equipment,  limiting  its  responsibility  to  the  repair  and  replacement  of  faulty 
parts.

 

 

Summary of Contents for 100M220

Page 1: ...aterial required 2 2 Components mounting 2 3 Water intake 2 4 Hydraulic connections 2 5 Electric connections 3 Operating procedures 3 1 Remote panel commands 3 2 First start up procedure 3 3 Normal op...

Page 2: ...alternative to the high pressure pumps of traditional plants utilizes the EN ERGY RECOVERY SYSTEM patented device which amplifies the pressure of common low pres sure pumps and recoup all the hydraul...

Page 3: ...15 cm Height 23 cm Dry weight 11 Kg Connections Seawater intake holder for hose int diam 20 mm Salt water outlet holder for hose int diam 20 mm Filters 5 micron 9 propylene Power supply Pump 230 VAC...

Page 4: ...n introduce inside the allen key also without remove the electric connector Turning clockwise the allen key increases the pressure shut down set whereas turning anti clockwise decrease the pressure sw...

Page 5: ...a beat issued periodi cally by the watermaker unit The unit is constituted of 2 cylinders and a central body containing the hydraulic valve necessary for the system functioning Manometer It is locate...

Page 6: ...lever The valve must be closed during normal functioning lever perpendicular to the valve Such valve has the function to allow the reset in case of a system block It must be opened be fore acting on t...

Page 7: ...p outlet and the watermaker inlet It is fitted with a 5 microns cartridge and protects the watermaker unit from sediments and de bris CA filter white It removes the chlorine from the washing fresh wat...

Page 8: ...necessary to create a suitable wooden or fiberglass structure for the unit if an existing one not available The base of the pump is equipped with vibration damping devices but avoid installing it on...

Page 9: ...d over Allow a minimum on off ball valve on the water intake The hose connections especially if under the seawater level must be secured with double hose clamps It is not advisable to Tee into the eng...

Page 10: ...ection that is continuously under consistent pressure is the pump outlet 5 m filter watermaker inlet connections For this section is necessary to use a good quality PN 15 min rein forced hose An inade...

Page 11: ...backflow valve pump inlet pump outlet 5 microns filter watermaker inlet PN 15 reinforced hose Section 20 mm int diam Low pressure max 3 bar connection watermaker s exhaust dis charge PN 5 stainless st...

Page 12: ...pressure amplifier inside the watermaker unit marked OUT Fresh water connection The connection has to be made using the small hose furnished with the equipment and relevant endowed fittings The conne...

Page 13: ...fer ential switch requested by the local law The section of the cables will be 4 mm2 min The computer box will be powered 12 24V directly from the service batteries or through a 230 12 24 charger Conn...

Page 14: ...14 Wiring connection diagram Watermaker pressure switch Elecrovalve Batteries or charger...

Page 15: ...uddenly It awaits for the correct positioning of the internal valve 2 3 seconds and then stops automatically If the automatic washing is activated washing light on the system once pushed STOP will per...

Page 16: ...or a general service The procedure allows to purge completely the air from the system and from the seawater and the washing fresh water hoses The depres surization valve must be opened before start th...

Page 17: ...e system It can be used as well after a filter replacement or after other maintenance operations Preliminary checks Verify that all components are connected correctly Verify that the filters cartridge...

Page 18: ...Exit from the menu pushing STOP Push WASHING for 3 seconds The display will indicate the remaining day before the first rinsing The function is anyway disabled pushing STOP or after a normal producti...

Page 19: ...mix carefully following the indications on the pack Wear a protection mask in order to avoid in haling product dusts The water temperature doesn t have to be lower than 25 C preferably 3 Close the gre...

Page 20: ...acement Every 6 months Close the grey valve before open the filter Purge periodically the air from the sys tem opening at 45 for a couple of min utes the depressuri zation valve Every 15 days Check th...

Page 21: ...allation water inlet net filter Low production normal or low pressure Exhausted batteries Air in the plant Seal system leak Check battery charge Perform bleeding Contact a Schenker service point Low p...

Page 22: ...nt accessories are guarantee 12 months starting from the date on the de livery document of the merchandise The guarantee does not include expendable materials car tridges active carbon filters membran...