S.B.C. Elettronica S.p.A. - Engineering Division
HPDxxN – High Power User’s Manual
22
3 - PARAMETERS AND PROGRAMMING
The features: torque, speed, acceleration and position control are the task of a dedicated electronic
circuits. In this chapter you can see how to set up and the meaning of any parameter, functional
block diagrams and advanced functions description too.
In the figure below it is described the general block diagram of the drive’s functions that you can
configure by parameters.
See chapter
Block diagrams
for a better description of how to use the drive, especially for
operating modes. See chapter
Pico-PLC
to understand how to connect peripheral systems
(inputs/outputs) to the parametric system of the HPD N drive.
Parameters are divided as follows:
The principal parameter units and resolutions are:
REFERENCE
MANAGER
LIMIT SWITCH
&
STOP
SPEED
REGULATOR
OPERATING
MODE
TORQUE
LIMIT
MANAGER
TORQUE DEMAND
analogue
digital
internal
MISCELLANEOUS
SPEED
WINDOWS
TORQUE
MODE
ACCEL.
MODE
MAINT.
MODE
POSITIO.
MODE
DIGITAL
LOCK
MODE
STEPPER
MODE
SPINDLE
ORIENT.
MODE
EXTERN.
MODE
TRIPS
MANAGER
b40.2
Pr31
from Pr0 to Pb42
basic parameters
from Pr50 to Pb70
operating mode parameters
from Pr71 to Pb99
pico-PLC parameters
from In0 to In63
pico-PLC instructions
parameter
unit
resolution
speed
revolutions per minute
1
acceleration
seconds / 1000 rpm.
0.001
position
4096 steps / revolution
1/4096 revolution
current
% of the drive peak current
0.1