4.2 Serial addresses and parameter lengths
Parameter
Address Length Meaning
Pr0
038h
2
motor speed in rpm
Pr1
034h
2
analogue reference
Pr2
03Ah
2
full scale 1
Pr3
03Ch
2
full scale 2
Pr4
036h
2
frequency full scale
Pr5
03Eh
2
internal reference
Pr6
040h
2
reserved reference
Pr7
042h
2
chosen reference
Pr8
0AEh
2
positive acceleration in seconds
Pr9
0B0h
2
positive deceleration in seconds
Pr10
0B2h
2
negative acceleration in seconds
Pr11
0B4h
2
negative deceleration in seconds
Pr12
0B6h
2
limit switch deceleration
Pr13
0B8h
2
overspeed threshold
Pr14
044h
2
top speed limit
Pr15
046h
2
lower speed limit
Pr16
048h
2
integral gain
Pr17
0BAh
2
damping factor
Pr18
0BCh
2
filter time constant
Pr19
0BEh
2
user current limit
Pr20
04Ah
2
DC bus voltage
Pr21
04Ch
2
reserved torque limit
Pr22
04Eh
2
auxiliary reference
Pr23
051h
1
current alarm code
Pr24
052h
1
previous alarm code
Pr25
053h
1
software version code
Pr26
05Eh
1
baud rate
Pr27
05Fh
1
serial address
Pr28
0C0h
2
shaft position (0..4095)
Pr29
061h
1
motor poles
Pr30
0C2h
2
resolver offset
Pr31
054h
1
operating mode
Pr32
0C4h
2
rated motor speed
Pr33
0C6h
2
rated current
Pr34
055h
1
scale factor for tacho generator
Pr35
0C8h
2
filtered torque request
Pr36
058h
2
i
2
t accumulation
Pr37
05Ah
2
thermal image for braking
Pr38
0CAh
2
auxiliary analogue output
Pr39
0CCh
2
K for phase advance